HUYGENS OPTICS
CS-2/3 camera strobe manual V01
14
Troubleshooting
Device not flashing:
1)
First Check green LED indicator on the back of the device. If green light is not lit or very dim:
check power supply voltage level, connections and polarity of the power source.
2)
If the green LED light is on and no flashes occur, check connections of the pulse input
connections, the polarity, and chek if the pulse level is between 4 and 24V.
Device flashing but very dimly:
1)
Power supply voltage too low, should be 12 V
2)
Internal electronics failure: please contact Huygens Optics.
Device flashing at correct level but not correctly timed:
1)
Check polarity of the trigger connections.
2)
Check for ghost pulses on the trigger connection
If you have tried all the above with no success, please remove the power from the device and
contact Huygens Optics for additional support.