1. How to check SW version
Page 1: ...ARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 Table of Contents 1 How to check SW version 2 Replacing Board 3 Replacing Cover 4 Sensor Position 5 Adjusting Cla...
Page 2: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 1 How to check SW version...
Page 3: ...Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 1 Checking SW Version 3 Check SW version GUI MOTOR 1 Select menu 2...
Page 4: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 2 Replacing Board...
Page 5: ...dger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 1 Open Cover 1 Loosen 2 bolts 2 Open the front cover GUI Board Motor...
Page 6: ...DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 2 Replace GUI board 1 Disconnect cables 2 Loosen 4 screws 3 Use original FRAM to use original setup data Recommend to take a pictur...
Page 7: ...OC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 3 Replace Motor board and Power board 1 Loosen 4 screws Disconnect cables for each board...
Page 8: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 3 Replacing Cover...
Page 9: ...VICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 1 Open Cover 1 Loosen 2 bolts 2 Open the front cover GUI Board and keypad bo...
Page 10: ...MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 2 Remove GUI board and Keypad 1 Disconnect cables 2 Loosen 4 screws of LCD Remove LCD with GUI board Some cables are tied to cover Cut cable ties i...
Page 11: ...VIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 3 Remove front cover 1 To replace front cover remove a connecting bar 2 Push the bar with screw driver 3 Pull the bar o...
Page 12: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 3 Sensor Position...
Page 13: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 1 PI Sensor Y Bottom PI Y Top PI R PI...
Page 14: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 1 Limit Switch Y Bottom Limit X Limit...
Page 15: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 3 Adjusting Clamp Power...
Page 16: ...IRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 Adjust Clamp Open Close Power 1 Select menu 2 Select Engineer menu 3 Select Clamp power Adjust Close Open Power Adjust Clamp Pro...
Page 17: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 3 Adjusting Wheel Position...
Page 18: ...ICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 Adjust Wheel position 1 Select menu 2 Select Engineer menu 3 Adjust wheel pos...
Page 19: ...PRODUCT Auto Lens Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 3 Adjusting Size and Margin...
Page 20: ...L DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 1 Adjust Size 1 Select menu 2 Select Engineer menu 3 Adjust lens size You can adjust s...
Page 21: ...s Edger SERVICE MANUAL DOC No SCS I 9ME 091 PREPARE REVIEW CONFIRM DATE 2013 12 25 MODEL CME 9000 REVISION DATE REVISON USE 2013 12 25 2 Adjust Margin 1 Select menu 2 Select Engineer menu 3 Adjust mar...