background image

Rev. 0505

1 3

Maintenance cont’d

Glass Sweep Installation

(WHERE APPLICABLE)

PARTS LIST
• Silicone 1200 (or comparable)
• Masking tap (not supplied)
INSTRUCTIONS

1.

Cut a strip of the glass sweep material to the proper
length.

2.

Open glass wide enough to apply a few small drips of
#1200 silicone down the edge of one side of the glass.
Space each drop about 4” apart.

3.

Apply the glass sweep strip to the freshly siliconed
end, making sure to align the edges top and bottom.
Carefully wipe up any excess silicone that may be
bubbling up from the edges.

4.

Apply tape across the strip, to hold it in place on edge
of glass until the silicone has a chance to properly dry
(approximately 30 minutes).

5

 Repeat process for strip on the other edge.

ELECTRIC AL PREC AUTIONS

BEFORE

SERVICING

Always Disconnect Electrical
Power at the Main Disconnect
when servicing or replacing
any electrical component.

This includes (but not limited to) Fans,
Heaters, Thermostats, and Lights.

ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN
DISCONNECT WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT. 

This includes (but not limited

to) fans, heaters, thermostats, and lights.

TIPS & TROUBLESHOOTING

BEFORE CALLING FOR SERVICE IF SOMETHING
SEEMS WRONG, CHECK THE FOLLOWING:

1. Check electrical power supply to the equipment for

connection.

2. Check fixture loading. Overstocking case or blocking

airflow will affect it’s proper operation.

3. If frost is collecting on fixture and/or product, check

that Humidity Control is working properly, and that
no outside doors or windows are open—allowing
moisture to enter store.

FOR PROMPT SERVICE

When Contacting the Factory
regarding problems, Be sure
to have the Case MODEL and
SERIAL NUMBER Handy.

This Information is on a plate
located on the case itself.

Summary of Contents for VGD

Page 1: ...VGM VGD Vertical Glass Service Deli Meat Fish Case P N VGM VGD 0505 Chino VGM VGD Vertical Glass Service Deli Meat Fish Case REV 0505 I n s t a l l a t i o n Operation M a n u a l INSTALLATION OPERAT...

Page 2: ...f Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrier immediately and request an inspection Hussmann Chino will acknowledge shortages within ten days from r...

Page 3: ...perature swings causing product dehydration and excessive energy consumption Defrost cycles should be set according to the Case Specifications in this book Clean humidity system a minimum of every 90...

Page 4: ...s full extension and lower Installation These steps should release any settled lubricant within the cylinders and prevent any stress on the front glass SETTING AND JOINING The sectional construction o...

Page 5: ...re by bolting the rear mullions tegether Do not use bolts to pull cases together 9 Apply bead of silicone to top of bulkheads and slip on stainless steel bulkhead cap Also apply silicone to seam betwe...

Page 6: ...trap supplied with the case 2 When connecting condensate drains the P trap must be used as part of the condensate drain to prevent air leakage or insect entrance Store plumbing system floor drains sh...

Page 7: ...oduct quality with the installation of the proper controlling devices These should be set according to the Hussmann s specifications and a prop erly maintained humidity system Incorrect settings and f...

Page 8: ...te on the case for information REFRIGERATION LINES LIQUID SUCTION 3 8 O D 5 8 O D NOTE The standard coil is piped at 5 8 suction however the store tie in may vary depending on the number of coils and...

Page 9: ...each night with a clean damp cloth or butcher paper never use plastic as it does not allow appearance and significantly shortening product shelf life 10 Cold coils remove heat and moisture from the ca...

Page 10: ...clean the non glare glass The damage to the glass from improper cautic solutions is irreparable In addition to cleaning the glass with the recommended product there are precautions that should be take...

Page 11: ...trol is working properly and that no outside doors or windows are open allowing moisture to enter store FOR PROMPT SERVICE When Contacting the Factory regarding problems Be sure to have the Case MODEL...

Page 12: ...ction gently tap loose or remove panel wedge the entire length of the panel Maintenance cont FOR PROMPT SERVICE When Contacting the Factory regarding problems Be sure to have the Case MODEL and SERIAL...

Page 13: ...s Disconnect Electrical Power at the Main Disconnect when servicing or replacing any electrical component This includes but not limited to Fans Heaters Thermostats and Lights ALWAYS DISCONNECT ELECTRI...

Page 14: ...AIR T STAT FAN SIZE FREQ AIR AIR HUNIDITY LENGTH REQ D EVAP PROD DISC VELOC CUT IN NUMBER FAN E E FANS RECEP SWEEP SWEEP SYSTEM APP FT TMP TMP TMP FPM SETTINGS EVAP COIL OF MOTORS QTY DURATION STANDA...

Page 15: ...F32T8 48 125 03 0241 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F32T8 48 12...

Page 16: ...FANS 1 COMAIR 125 01 2011 M F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28...

Page 17: ...NS 1 COMAIR 125 01 2011 M F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5...

Page 18: ...03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F3...

Page 19: ...0311 CIRCUIT 1 W G BK DUPEX OUTLET SINGLE OUTLET W G BK AIR SWEEP FANS 3 COMAIR 00001212 M M M F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241 F32T8 48 125 03 0241...

Page 20: ...W G BK DUPEX OUTLET SINGLE OUTLET W G BK AIR SWEEP FANS 3 COMAIR 00001212 M M TOP FRONT LIGHTS OPTIONAL LIGHTS TERMINAL BLOCK 125 01 0295 SHELF LIGHT NOSE LIGHT LEDGE LIGHT F21T5 36 125 03 1129 F21T5...

Page 21: ...complete start up evaluation prior to the loading of food into the refrig erator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant accordi...

Page 22: ...or blade inoperative 14 Is the defrost time excessive 15 Is the defrost termination thermostat if used set too high 16 Are the refrigerant controls incorrectly adjusted 17 Is the air entering the cond...

Page 23: ...this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor ass...

Page 24: ...lar unit They can be found on a small metal plate on the unit Please note them below for future reference M O D E L SERIAL NUMBER Chino Additional copies of this publication may be obtained by contact...

Reviews:

Related manuals for VGD