Hussmann TY3ECRC Installation & Operation Manual Download Page 20

20

• USE WATER AND A MILD DETERGENT FOR THE  

EXTERIOR ONLY

• Wipe interior with damp non-abrasive cloth. Soap and  

hot water are not enough to kill bacteria; a sanitizing  
solution must be included with each cleaning process to  
eliminate bacteria.

• Clean any visible debris surrounding or on top of the  

drain location. The drain is located under the deck pans.

• DO NOT USE A CHLORINATED CLEANER ON ANY  

SURFACE.

• DO NOT USE ABRASIVES OR STEEL WOOL SCOUR-

ING PADS (these will mar the finish)

• DO NOT Use a cleaning or sanitizing solution that

has:

• OIL BASE (these will dissolve the  butyl

sealants)

• AMMONIA BASE (these will corrode the

copper components of the case)

• ACID Base (these will pit and damaged 

metal finishes

• DO Not Use chlorinated sanitizing solutions

General Maintenance

Inspect and clean condenser coil monthly. Clean
using a vacuum cleaner with a wand attachment 
and a soft (non-metallic) brush to remove dirt and 
debris. DO NOT bend fins. Always wear gloves and 
protective eyewear when cleaning near sharp coil 
fins and dust particles. When properly  cleaned, you 
should be able to see through the  condenser coil

Inspect drain screens for debris. Remove if present. 
DO NOT put debris down the drain

Inspect honeycomb for dust buildup. Remove and 
clean with water and mild soap

Ensure no price tags, placards, debris, or 
merchandising garnish is sitting in the return air

Ensure shelves are not stocked outside of their limits 
(See Load limit representation on page 22)

Case Cleaning

To ensure long life, proper sanitation and minimum 
maintenance costs, the refrigerator should be thoroughly 
cleaned frequently. SHUT OFF FAN BEFORE 
CLEANING: It can be unplugged within the case, or shut 
off entire case at the source. The interior bottom may be 
wiped with any domestic soap or detergent based 
cleaners.

WARNING! DO NOT USE WATER HOSES!

A self

contained case empties into an evaporator pan that WILL 
OVERFLOW IF TOO MUCH WATER IS INTRODUCED
during cleaning

Plexiglass and Acrylic Care

Improper cleaning not only accelerates the cleaning cycle
but also degrades the quality of this surface. Normal daily
buffing motions can generated static cling attracting dust to
the surface. Incorrect cleaning agents or cleaning cloths can
cause micro scratching of the surface, causing the plastic to
haze over time.

Hussmann recommends using a clean damp chamois, or a
paper towel marked as “dust and abrasive free” with 210

®

Plastic

Cleaner and Polish available by calling Sumner Labs at 1-800-
542-8656. Hard, rough cloths or paper towels will scratch the
acrylic and should not be used.

Sanitizing

It is essential to establish a regular cleaning procedure.
This will minimize bacteria causing discoloration which leads
to degraded product appearance and significantly shortening
product shelf life.
Soap and hot water are not enough: A sanitizing solution
must be included with each cleaning process to eliminate
this bacteria. Sanitizing solutions will not harm the interior
bottom, however, these solutions should always be within
the following guidelines:

1. Scrub thoroughly, cleaning all surfaces, with soap  

and hot water.

2. Rinse with hot water, but do not flood.
3. Apply the sanitizing solutions that meet the 

guidelines above.

4. Rinse thoroughly.
5. Dry completely before resuming operation.

Summary of Contents for TY3ECRC

Page 1: ...CRC and TYA3ECRC END ISLAND CASE SELF CONTAINED Installation Operation Manual REV 0421 INSTALLATION OPERATION GUIDE TY3ECRC and TYA3ECRC ENTYCE END ISLAND CASE EXTENDED CANOPY ROUND CORNER SELF CONTAI...

Page 2: ...11 Clearances for Case 12 Body Panel Removal 13 Lifting Instructions 14 15 Electrical Information 16 Electrical Components 16 Wiring Diagram Information 17 Case Parameters 17 Controller Operation Guid...

Page 3: ...ue 2 Never stand on the EntyceTop Deck or any Shelves for any reason These surfaces are not steps and are not designed to support such loads Misusing these surfaces as steps will result in damage to t...

Page 4: ...ion within 15 days and retain all packaging The carrier will supply inspection report and required claim forms Location Store Conditions The refrigerated merchandisers have been designed for use only...

Page 5: ...proper draining of condensate Plumbing Check Initial Case condensate Floor sink Electric Evap pan Condensate pump There are no water leaks from the case Refrigeration Check Initial This case applicat...

Page 6: ...normal case operation at startup Hussmann Tech Support 866 785 8499 General Maintenance Self contained applications Keeping the condenser coil clean will minimize required service and lower electrical...

Page 7: ...Cut and Plan Views 7...

Page 8: ...EFROST WATER LBS DAY FT USAGE SET POINT F DIFFER ENTIAL F TYPE 1 24 12 OFF TIME 50 12 46 N A 12 TYPE 2 24 12 OFF TIME 50 12 46 N A 14 5 ELECTRICAL DATA STANDARD FANS HEATERS LED LIGHTS 115 VOLT CASE L...

Page 9: ...OFF TIME 40 12 46 N A 3 8 5 5E 22 8 OFF TIME 40 12 48 N A 3 8 ELECTRICAL DATA STANDARD FANS HEATERS LED LIGHTS 115 VOLT CASE LENGTH EVAPORATOR FANS CANOPY LIGHTS LED OPTIONAL LED SHELF LIGHTS MAX LED...

Page 10: ...ND PANEL WIDTH KEY OF END PNLS END PNL WIDTH IN TOTAL ADDED LENGTH IN 1 1 125 1 125 CASE LENGTH CANOPY LIGHTS H O LED OPTIONAL SHELF MAX H O LED LOAD AMPS WATTS AMPS WATTS AMPS WATTS 6E N A N A N A N...

Page 11: ...Remove the top of the crate Detach the walls from each other and remove from the skid Unbolt the case from the skid The fixture can now be lifted off the crate skid Lift only at base of stand See pag...

Page 12: ...clearance measured from floor follows as a minimum of 10 ft vertically Minimum of 36 in clearance if near an open aisle is required for proper cycle ventilation Assumed 8 ft clearance from solid wall...

Page 13: ...To attach the body panels back onto the merchandiser fol low the steps in reverse order 13 Body Panel Removal The merchandiser s body panels are designed with slots located on top and bottom The body...

Page 14: ...lifting with a jack Serious damage will occur if the body panels are not removed see pg 13 for body panel removal 3 The Entyce can be raised at one end to allow the placement of rollers or dollies the...

Page 15: ...not satisfy the safe lift of the merchandiser Place Dollies and chock wheels before lifting the other side Be sure that the dollies are evenly spaced inorderto carry weight of the case Evaporator Pan...

Page 16: ...Stat Solenoid115VAC White Black T Stat Solenoid 24VAC Red White Fan Motors Brown Blue Condensing Unit Use Copper Conductors Only 430 01 0338 R101003 DANGER BEFORE SERVICING ALWAYS DISCONNECT ELECTRICA...

Page 17: ...Shelf Lights Wiring Diagram Access A Wiring diagram was shipped with the case and packaged with this Installation Manual If the diagram is missing or misplaced please contact Hussmann page 4 or 29 for...

Page 18: ...ered more of a right to know law than a pure product safety law When used as designed Hussmann believes that our products are not harmful We provide the Proposition 65 warning to stay in compliance wi...

Page 19: ...ration control systems 1 2 3 Open Camera 19 IPhone User Hold the camera up to the QR code Android User Open QR Code Reader app if necessary Hold the camera up to the QR code Tap the notification to be...

Page 20: ...ce costs the refrigerator should be thoroughly cleaned frequently SHUT OFF FAN BEFORE CLEANING It can be unplugged within the case or shut off entire case at the source The interior bottom may be wipe...

Page 21: ...F dry heat 3 Install honeycomb by inserting the notched side up against the deflector and press upwards inserting the bottom of the honeycomb into the back ledge Slide along the honeycomb pressing the...

Page 22: ...lue must be unobstructed at all times to provide proper refrigeration 6 Avoid the use of supplemental flood or spot light ing Display light intensity has been designed for maximum visibility and produ...

Page 23: ...umb Check evaporator fan for cleanliness Unplug fan motors check motor shaft for excessive bearing wear Check the fan motors are securely mounted in brackets Verify that fan blades are securely mounte...

Page 24: ...from the bulbs to prevent flickering Check to ensure voltage at LED Driver If voltage is entering but not exiting the LED Driver LED Driver is faulty Check that ALL lights are plugged in and receptacl...

Page 25: ...H56892500 1H56892500 1H56892500 1H56892500 Thermal Expansion Valve 3002476500 3002476500 3002476500 3002476500 Sensor AKS 11 COIL OUT 1H90012500 1H90012500 1H90012500 1H90012500 Sensor AKS 12 DISCHARG...

Page 26: ...e found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of this publication may be obtained by contacting Hussmann Chino 1377...

Reviews: