Keep this booklet with the case at all times for future reference.

General Instructions

Table of Contents

General Instructions.....................................................2

Cut and Plan views ......................................................3

Installation .....................................................................4

Location ..................................................................................... 4

Uncrating the Stand ................................................................... 4

Exterior Loading ......................................................................... 4

Setting and Joining .................................................................... 4

Leveling ..................................................................................... 4

Splash Guard ............................................................................. 5

Plumbing .......................................................................6

Waste Outlet and P-TRAP ......................................................... 6

Access Panels ........................................................................... 6

Installing Condensate Drain....................................................... 6

Hose Reel .................................................................................. 6

Spray Hose ................................................................................ 6

Refrigeration .................................................................6

Refrigerant Type ........................................................................ 6

Piping ......................................................................................... 6

Access Panels ........................................................................... 6

Refrigeration Lines ..................................................................... 6

Control Settings ......................................................................... 6

Access to TX Valves and Drain Lines ........................................ 7

Electronic Expansion Valve (Optional) ....................................... 7

Thermostatic Expansion Valve Location .................................... 7

Measuring the Operating Superheat.......................................... 7

T-STAT Location ........................................................................ 7

Electrical........................................................................7

Wiring Color Code ..................................................................... 7

Electrical Circuit Identification

 .................................................... 7

Electrical Service Receptacles (When Applicable) .................... 7

Field Wiring and Serial Plate Amperage .................................... 8

Ballast Location ......................................................................... 8

Wiring and Serial Plate Amperage ............................................. 8

Ashrae Color Code .................................................................... 8

User Information ...........................................................8

Stocking ..................................................................................... 8

Important Steps ......................................................................... 8

Case Cleaning ........................................................................... 8

Maintenance ..................................................................9

Replacing Fluorescent Lamps ................................................... 9

Replacement Lamp Part List ..................................................... 9

T-5 Bulbs .................................................................................... 9

Evaporator Fans ........................................................................ 9

Copper Coils .............................................................................. 9

Tips and Troubleshooting ........................................................ 10

Electrical Wiring Diagrams ........................................10

Wiring Diagrams ......................................................... 11

Appendices .................................................................19

Appendix A. - Temperature Guidelines - Refrigerated ............. 19

Appendix B. - Application Recommendations - Refrigerated ... 19

Appendix C. - Field Recommendations - Refrigerated ............ 19

Appendix D. - Recommendations to User - Refrigerated ........ 0

This Booklet Contains Information on:

DSI-03, DSRPI-03 & DSI03-Y, DSRPI-03Y 

Island Produce 

Cases 

Shipping Damage

All equipment should be thoroughly examined for shipping 

damage before and during unloading.
This equipment has been carefully inspected at our factory 

and the carrier has assumed responsibility for safe arrival. 

If damaged, either apparent or concealed, claim must be 

made to the carrier.

Apparent Loss or Damage

If there is an 

obvious loss or damage

, it must be noted on 

the freight bill or express receipt and signed by the carrier’s 

agent; otherwise, carrier may refuse claim. The carrier will 

supply necessary claim forms.

Concealed Loss or Damage

When loss or damage 

is not apparent until after equipment 

is uncrated

, a claim for concealed damage is made. Make 

request in writing to carrier for inspection within 15 days, 

and retain all packaging. The carrier will supply inspection 

report and required claim forms.

Shortages

Check  your  shipment  for  any  possible  shortages  of 

material. If a shortage should exist and is found to be the 

responsibility of Hussmann Chino, 

notify Hussmann Chino

If such a shortage involves the carrier, 

notify the carrier 

immediately

, and request an inspection. Hussmann Chino 

will acknowledge shortages within ten days from receipt 

of equipment.    

Hussmann Chino Product Control

The  serial  number  and  shipping  date  of  all  equipment 

has been recorded in Hussmann’s files for warranty and 

replacement part purposes. All correspondence pertaining 

to warranty or parts ordering must include the serial number 

of each piece of equipment involved, in order to provide 

the customer with the correct parts. 

This equipment is to be installed

to  comply  with  the  applicable

NEC, Federal, State, and Local

Plumbing  and  Construction

Code  ha ving  jurisdiction.

Summary of Contents for Specialty Products DSI-03

Page 1: ...PI 03 DSI03 Y DSRPI 03Y ISLAND PRODUCE p n IGIP DSI 03 DSRPI 03 DSI03 Y DSRPI 03Y 0508 INSTALLATION OPERATION GUIDE CHINO DSI 03 DSRPI 03 DSIO3 Y DSRPI 03Y ISLAND PRODUCE Rev 0508 Installation Operati...

Page 2: ...s Information on DSI 03 DSRPI 03 DSI03 Y DSRPI 03Y Island Produce Cases Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has b...

Page 3: ...DSRPI 03Y Impact Plan View Scale 1 8 DSRPI 03 Shelf Rack Option Scale 3 8 DSRPI 03 DSRPI 03Y Impact Standard Section Scale 3 8 DSI 03 DSI 03Y Impact Standard Section Scale 3 8 Vision 16 9 3 8 Drain O...

Page 4: ...as close to its permanent position as possible Remove the top of the crate Detach the walls from each other and remove from the skid Unbolt the case from the skid The fixture can now be lifted off the...

Page 5: ...ty to install case s according to local construction and health codes 6 Slide second case up to first case snugly Then level second case to the first case so glass front bumper and top are flush 7 App...

Page 6: ...to prevent freezing The water seal should be insulated to prevent condensation Hose Reel If an optional hose reel is ordered it will be installed at the factory The water supply valve is located next...

Page 7: ...rator outlet 2 From a refrigerant pressure temperature chart determine the saturation temperature at the observed suction pressure 3 Measure the temperature of the suction gas at the thermostatic remo...

Page 8: ...the air in and around the case area free of foreign gasses and fumes or food will rapidly deteriorate 3 Maintain the display merchandisers temperature controls as outlined in the refrigerator section...

Page 9: ...orescent Lamps Fluorescent lamps are furnished with a shatterproof protective coating The same type of lamp with protective coating must be used if replaced This lamp has been treated to resist breaka...

Page 10: ...trol is working properly and that no outside doors or windows are open allowing moisture to enter store FOR PROMPT SERVICE When contacting the factory be sure to have the Case Model and Serial Number...

Page 11: ...21 00 Refrigerated Island Produce Stand W0900006 DSRP 18 Remote Evaporator w Fan Motors Liquid Solenoid opional T Stat optional Tx Valve optional 15V 3 6A Labeled Controller MOTOR S Computer Case Cont...

Page 12: ...L1 N L 125 02 0030 2 125 03 1077 2 125 02 0031 3 125 03 1080 FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FI...

Page 13: ...1 50 60 Hz L1 L2 L3 N G L LIGHT SWITCH TIPPETTE 125 01 0311 CIRCUIT 1 BLUE BLUE YELLOW YELLOW RED RED BALLAST 125 01 3278 B228PUNV C F35T5 60 125 03 1135 F35T5 60 125 03 1135 LIGHT SWITCH 125 01 8509...

Page 14: ...208 240 VAC 60 Hz SWITCH 125 01 0271 BUNDLE BLUE THERMOSTAT 225 01 2010 T X 4 N 3 1 2 DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715 PRESSURE SAFETY 225 01 0706B COND FAN 208 VAC BUNDLE BROWN...

Page 15: ...3 125 03 0012B 125 02 0020 4 125 03 0037A 4 M M M M M FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA L1 N 120 VAC 60 Hz MCA 3 2...

Page 16: ...03 0037A 4 M M M M M M M M FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA FIXTURE LITHONIA BUNDLE ORANGE L1 N 120 VAC 60 Hz MCA...

Page 17: ...AGE OF 1 1 9 6 07 Northgate 18 W0900025 DSRPI 03 6x12 BUNDLE BROWN 120 VAC 1 60 Hz M M BLK 14 WHITE 14 EVAP FAN MOTORS 2 GE 9W CW W 125 01 0614 9W 33A 120VAC L1 N MCA 74A MOP 15A BUNDLE BROWN 120 VAC...

Page 18: ...16 663363 CIRCUIT 1 NOTE CASE MUST BE GROUNDED 12 7 10 9 12 7 10 9 L1 L2 208 V 240 V LOADING CONDENSING UNIT COPELAND FJAM A200 CFV 020 1H10402500 DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715...

Page 19: ...er should perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a r...

Page 20: ...loaded with warm product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air f...

Page 21: ...ure recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising products to ensure that potenti...

Page 22: ...__________________ _______________ ___________________________________________________________________________________________________ _______________ _________________________________________________...

Reviews: