Electrical

5

/

8

(92)

23 

7

/

8

(608)

18 

1

/

2

(470)

C

O

I

L

FAN

FA

N

Refrigeration

Outlet

11 

3

/

4

(298)

34

(867)

13 

3

/

4

(349)

44 

5

/

8  

(1133)

33 

3

/

8  

(848)

28 

3

/

4  

(730)

25 

5

/

8  

(651)

SLGV

24 

1

/

2

(622)

52

(1321)

20

(508)

COIL

Impact  

SLGV

Low Temp Specialty Seafood

Dimensions shown as in. & (mm).

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

SLGV

Discharge Air (°F)

–12

Evaporator(°F)

–20

Unit Sizing (°F)

–23

Btu/hr/ft

SLGV

Parallel

430

Conventional

460

DEFROST DATA

SLGV

Frequency (hr)

24

Defrost Water (lb/ft/day)

0.25

(± 15% 

based on case configuration and

product loading).

E

LECTRIC

SLGV

Temp Term (°F)

NA

Failsafe (minutes)

30

O

FFTIME OR

G

AS

Not Recommended 

Standard Defrost Thermostat — NA

CONVENTIONAL CONTROLS

Low Pressure Backup Control

SLGV

CI/CO

*

–27°F / –37°F

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)*

Not Recommended

*

Use a Temperature Pressure Chart to

determine PSIG conversions.

PHYSICAL DATA

Merchandiser

SLGV

Drip Pipe (in.)

1 1/2

Liquid Line (in.)

3/8

Suction Line (in.)

5/8

Estimated Charge (lb)**
4 ft 

0.8

6 ft

1.2

8 or 12 ft 

NA

**This is an average for all refrigerant
types. Actual refrigerant charge may vary
by approximately half a pound.

Length Added to Lineup by:
Each Plastic End w/Bumper (in.)

1

/

2

Each End/Partition (in.)                 

1

/

2

Multi-Paned Flat Glass, Gravity, 3 Display Level

NSF Certification

These merchandisers are manufactured to meet ANSI /National

Sanitation Foundation (NSF

®

) Standard #7 requirements. 

Summary of Contents for SLGV

Page 1: ... 6 ft case HE 4850722 E Defrost Heater Gravity Coil 208V 5 0486058 4 ft case HE 4850705 0486059 6 ft case HE 4850706 F Defrost Heater Blower Coil 208V 6 0486056 4 ft case HE 4850703 0486057 6 ft case HE 4850704 LAMPS AND BALLASTS G 0355716 Ballast Electronic 2 lamps BA 0355716 7 H Fluorescent Lamp 8 Replace with like fixtures SLGV Technical Data Sheet P N 0432520_B NSF Certified July 2007 2007 HUS...

Page 2: ... mm to the length of the lineup Electrical Service B RH end of case to Electrical raceway right edge 7 178 7 178 C RH end of case to Electrical raceway left edge 41 3 8 1051 32 3 4 831 Back of case to center of knockout 3 5 8 92 3 5 8 92 Electrical Field Wiring Connection Point Waste Outlet D RH end of case to the center of waste outlet 24 610 24 610 Back of case to center of waste outlet 25 5 8 6...

Page 3: ...tion and product loading ELECTRIC SLGV Temp Term F NA Failsafe minutes 30 OFFTIME OR GAS Not Recommended Standard Defrost Thermostat NA CONVENTIONALCONTROLS Low Pressure Backup Control SLGV CI CO 27 F 37 F Indoor Unit Only Pressure Defrost Termination Temp F Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser SLGV Drip Pipe in 1 1 2 Liquid Line...

Page 4: ...0 52 1 04 1 04 1 56 30 60 60 90 Energy Efficient NA NA NA NA NA NA NA NA Export 230V 50 hz NA NA 0 36 0 54 NA NA 60 90 Anti sweat Heaters on Fan Circuit 1 28 1 92 NA NA 154 230 NA NA Constant On Anti sweat Heaters NA NA NA NA NA NA NA NA Cycling Anti sweat Heaters NA NA NA NA NA NA NA NA Minimum Circuit Ampacity With Standard Fans 60 hz 2 31 3 95 1 82 2 63 With Energy Efficient Fans NA NA NA NA Wi...

Page 5: ...R Red G Green BL Blue LB Light Blue DB Dark Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only Evaporator Fan and Anti Sweat Heaters Electric Defrost Heaters Ambient Air Wipe Fans L1 208V POWER FROM DEFROST CONT...

Page 6: ... POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only 120V NEUTRAL ORANGE OR TAN BAND 120V POWER ORANGE OR TAN BAND B BL 7 8 R G 8 7 R BL G W B Optional Lighting Ledge Light Standard Lighting LIGHT SWITCH ...

Reviews: