background image

IGSSB-SHVSS-0302

8

USER INFORMATION

STOCKING

In order to maximize product life, maintain a constant and
proper product temperature from the time the product is
received through storage, preparation and display.

Products should not be placed in merchandisers until all
refrigeration controls have been adjusted and merchandis-
ers are at proper operating temperature. Care should be
taken to place the bakery trays all the way to the front of
the shelf. This avoids blocking the rear refrigerated air dis-
charge. The load limit decals are affixed to the interior of
the merchandiser. Again, air discharge and return air
flue must be unobstructed at all times to provide
proper refrigeration.

There is also a row of vents located at the base of the
front glass, just above the front rub rail. These vents allow
a gentle air flow across the front glass from the ambient
fans that prevents any condensation on the glass. Do Not
place any signs or other restrictive objects on the
front of the merchandiser that will block these

ARE AND CLEANIN

CARE AND CLEANING

Long life and satisfactory performance of any equipment is
dependent upon the care it receives. To ensure long life,
proper sanitation and minimum maintenance costs, mer-
chandisers should be thoroughly cleaned, all debris removed
and the interiors washed down, weekly.

Warning - Do Not use HOT water on COLD glass
surfaces. This can cause the glass to shatter and
could result in personal injury. Allow glass fronts,
ends and service doors to warm before applying
hot water.

Exterior Surfaces - The exterior surfaces must be cleaned

with a mild detergent and warm water to protect and
maintain their attractive finish. Never use abrasive
cleansers or scouring pads.

Front Glass - DO NOT use the front glass as a support
during cleaning. Removal of the glass is NOT recommended.

Interior Surfaces - The lower display decks are remov-
able by sliding open rear drawer and lifting them up and
out. The interior surfaces may be cleaned with most do-
mestic detergents, ammonia based cleaners and sanitizing
solutions with no harm to the surface.

CAUTION: SHUT FAN OFF DURING CLEANING

IMPORTANT STEPS

1.

For temperature settings, please see the Case
Specifications section in this book.

2.

Temperature control should be by means of a T-Stat
and Suction Stop Solenoid at each case. Do not use
EPR valves, Liquid Line Solenoids or electronic
control devices of any kind, as these allow
temperature swings causing dehydration and
excessive energy consumption.

3.

Product should be worked and rotated on a regular
basis, not to exceed a 4-hour period.

4.

At night, turn off case lights and cover the product
with a damp (not wet) cloth similar to cheese cloth
(etc.). This should be washed out in the morning and
kept in a walk-in box during the day—so that it is cool
and moist when covering the product.

5.

Discharge air temperature should be approximately
26°F, with between 150-200 FPM air velocity. Do not
display product directly within the air discharge.

6.

Clean Humidity system a minimum of every 90 days
for proper system operation.

Summary of Contents for SHVSS

Page 1: ... Chino SHVSS Summit High Volume Self Service Bakery Case REV 0302 Installation Operation Manual SHVSS Summit High Volume Self Service Bakery Case P N IGSSB SHVSS 0302 INSTALLATION OPERATION GUIDE ...

Page 2: ... When loss or damage is not apparent until after equipment is uncrated a claim for concealed damage is made Make request in writing to carrier for inspection within 15 days and retain all packaging The carrier will supply inspection report and required claim forms SHORTAGES Check your shipment for any possible shortages of material If a shortage should exist and is found to be the responsibility o...

Page 3: ... not set temperature too cold as this causes product dehydration Temperatures should be achieved by a t stat and suc tion solenoid at each case Do not use EPR valves liq uid line solenoids or electronic control devices of any kind These controls allow temperature swings causing product dehydration and excessive energy consumption Defrost cycles should be set according to the Case Specifications in...

Page 4: ...hich means that two or more may be joined in line yielding one long continuous display requiring only one pair of ends Joint kits and instructions are shipped separately ACES SHIPPING BRACES NOT ALL MERCHANDISERS Move the fixture as close as possible to its permanent location and then remove all packaging Check for damage before discarding packaging Remove all sepa rately packed accessories such a...

Page 5: ...diam eter of the pipe or water seal supplied with the mer chandiser 2 When connecting drip piping the water seal must be used as part of the drip piping to prevent air leakage or insect entrance Never use two water seals in series in any one drip pipe Double water seals in series will cause an air lock and prevent draining 3 Pitch the drip piping in the direction of flow There should be a minimum ...

Page 6: ...s provided for this purpose DO NOT RUN REFRIG ERANT LINESTHROUGH MERCHANDISERS THAT ARE NOTTHE SAME REFRIGERATION SYSTEM as this may result in poor refrigeration control and compressor failure Line Sizing Refrigerant lines should be sized as shown on the refrigeration legend that is furnished for the store not furnished by Hussmann If a legend has not been furnished refer to the Hussmann Applicati...

Page 7: ... 3 50 In 1 2 115 18 0 Air 2 6 30Out 5 4300 20 40 30 225 Opt Forced 4 1 2 36 min 28 1 12 3 50 In 1 2 115 18 0 Air 2 6 30Out 6 5160 20 40 30 225 Opt Forced 4 1 2 36 min 42 3 36 3 50 In 3 4 115 18 5 Air 3 30Out NOTES These refrigerated merchandisers have been designed for use in stores where temperatures and humidity are maintained at or below 75 F and 55 RH Stores are responsible for setting their c...

Page 8: ...t in personal injury Allow glass fronts ends and service doors to warm before applying hot water Exterior Surfaces The exterior surfaces must be cleaned with a mild detergent and warm water to protect and maintain their attractive finish Never use abrasive cleansers or scouring pads Front Glass DO NOT use the front glass as a support during cleaning Removal of the glass is NOT recommended Interior...

Page 9: ...l wiring must be in compliance with NEC and local codes All electrical connections for the nonrefrigerated model are to be made in the electrical panel Electrical connections for refrigerated models are made in the electrical box on the back of the case behind the rear close off panel Field Wiring Field wiring must be sized for compo nents amperes stamped on the serial plate Actual ampere draw may...

Page 10: ...essure Safety 115V 1Ø 60 Hz 20A Compressor Motor 115V 3 4HP 11A RLA Start Capacitor Condensing Fan black yellow 8045 00 120V 125 01 0710 Paragon Timer S C T X 4 N 3 1 2 S R 3 1 2 C MOTOR 5 2 1 1 3 2 1 3 Control Panel J BOX red black yellow black T Stat Start Capacitor Run Capacitor red blue black red C R T X 4 N 3 1 S R 3 1 2 C MOTOR 5 2 1 MagneTek B 332i120RH blue blue 1 3 2 1 3 2 2 2 1 3 2 1 3 r...

Page 11: ...3 4HP 6 7A RLA Condensing Fan Paragon Timer T X 4 N 3 1 2 S R 3 5 2 1 1 3 2 1 3 J Panel J BOX 12 black T Stat red T N 1 1 2 C MOTOR MagneTek B 332i120RH blue blue 1 3 2 1 3 2 2 2 1 3 2 1 3 red 3 Pins male harness red red Cap LIGHTS Cap F40T8 SPX35 F40T8 SPX35 F40T8 SPX35 1 2 3 Crown Light hard wiring Shelves Lights 3 Pins male harness 3 Pins male harness M M M 2 wires Female harness 3 12 black 12 ...

Page 12: ...up evaluation prior to the loading of food into the refrig erator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant according to Hussmann s recommendations b Observation of outside influences such as drafts radiant heating from the ceiling and from lamps Such influence should be properly corrected or compensated for c At the same time ch...

Page 13: ...e evaporator fan motor blade inoperative 14 Is the defrost time excessive 15 Is the defrost termination thermostat if used set too high 16 Are the refrigerant controls incorrectly adjusted 17 Is the air entering the condenser above design condi tions Are the condenser fins clear of dirt dust etc 18 Is there a shortage of refrigerant 19 Has the equipment been modified to use replacements for CFC 12...

Page 14: ...a tion h Keep tools clean and sanitized Since mechanical equipment is used for fresh meat processing all suchequipmentshouldbecleanedatleastdailyand each time a different kind of meat product comes in contact with the tool or equipment i Make sure that all refrigeration equipment is in stalled and adjusted in strict accordance with Hussmann s recommendations j See that all storage and refrigeratio...

Page 15: ...under this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor assem bly is available but must be purchased prior to shipment to be in effect Hussmann reserves the right to inspect the job site installation and reason for failure The motor compressor warranties...

Page 16: ...articular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of thispublication may be obtained by contacting Hussmann Chino 13770 RamonaAvenue Chino California 91710 909 628 8942 FAX 909 590 4910 800 395 9229 Service Record Last service date By ...