background image

5 of 6

P/N 0492426_B

Light Blue

2

To 
Condensing Unit

}

Refrigeration Thermostat

1

3

Anti-sweat Heaters

B

ROWN

  B

AND

Fans

B

ROWN

  B

AND

120V POWER

1

B

ROWN

  B

AND

B

ROWN

  B

AND

120V NEUTRAL

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

=  Field G

ROUND

=  Case G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

 
 

 
 

8 ft 

10 ft 
12 ft 
14 ft 
16 ft

6, 8, 10, 14 & 16 Fans

Fan  Wiring 
Offtime Defrost

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Summary of Contents for RI3

Page 1: ...47 CT 4481631 Item Part Description Wiring Item HEATERS C Anti Sweat Heater 3 0487118 HE 4850668 LAMPS AND BALLASTS D Ballast Electronic 4 0355398 BA 4480118 0355716 BA 0355716 0447740 BA 4481278 0459491 BA 4481566 E Fluorescent Lamp 5 Replace with like fixtures 2006 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reserve the r...

Page 2: ...8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93 ...

Page 3: ...e Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb 8 ft 1 7 10 ft 2 1 12 ft 2 5 14 ft 3 1 16 ft 3 7 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound RI3 Multi deck Islan...

Page 4: ...0 57 0 68 84 84 108 132 156 Minimum Circuit Ampacity MCA 120V 60Hz Standard 5 27 6 57 8 20 11 13 12 77 120V 50Hz Standard 5 31 6 81 8 48 11 66 13 33 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 61 3 21 3 98 5 36 6 13 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Current Protection 230V 15 1...

Page 5: ...UTRAL R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 8 ft 10 ft 12 ft 14 ft 16 ft 6 8 10 14 16 Fans Fan Wiring Offtime Defrost HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Page 6: ... G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit Typical Shelf Ballast Wiring Maximum lamps per ballast is four 4 Different shelf config...

Reviews: