RI2

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

RI2 Island

A

B

Electrical Service

Drains

Refrigeration 

& Coil Stubout

27 

(686)

(178)

49 

(1245)

32

 

1

/2

 

(826)

11

 

1

/2

 

(292)

9

 

1

/2

 

(241)

22 

(559)

72 

(1829)

31

 

1

/4

 

(794)

20

 

3

/8

 

(518)

Engineering

Plan Views

06-2003

Front

8 ft

10 ft

12 ft

14 ft

16 ft

General

(A)

Base Length

77 (1956)

101 

7

/

(2588)

125 

7

/

(3198)

149 

1

/

(3798)

173 (4396)

Overall Case Length

96 (2438)

120 (3048)

144 (3658)

168 (4267)

192 (4876)

Maximum O/S dimension of case back to front 

(includes bumper)

72 (1829)

72 (1829)

72 (1829)

72 (1829)

72 (1829)

Front of splashguard to O/S edge of front base rail

5

/

(41)

5

/

(41)

5

/

(41)

5

/

(41)

5

/

(41)

Front of case to O/S edge of front base rail

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

13 

1

/

(333)

Back of case to O/S edge of front base rail

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

58 

7

/

(1495)

Width of base rail

7

/

(48)

7

/

(48)

7

/

(48)

7

/

(48)

7

/

(48)

Electrical Service                             

(Electrical Field Wiring connection point)

Center of Electrical service to O/S edge of front base rail

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

46 

1

/

(1181)

Right end of case to center of knockout

27 (686)

27 (686)

27 (686)

27 (686)

27 (686)

Left end of case to center of knockout

69 (1753)

93 (2362)

117 (2972)

141 (3581)

165 (4191)

Waste Outlets

(B)

LH End of case to the center of waste outlet

48 (1219)

78 (1981)

102 (2591)

84 (2134)

96 (2439)

Center of front waste outlet to outside of front base rail

8 (203)

8 (203)

8 (203)

8 (203)

8 (203)

Center of back waste outlet to outside of front base rail

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

39 

1

/

(997)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

LH end of case to center of refrigeration outlet

22 (559)

22 (559)

22 (559)

22 (559)

22 (559)

RH end of case to center of refrigeration outlet

74 (1880)

98 (2489)

122 (3098)

146 (3708)

170 (4318)

Serial Plate
End

Summary of Contents for RI2

Page 1: ...t 2 0448347 CT 4481631 Item Part Description Wiring Item HEATERS C Anti Sweat Heater 3 0487118 HE 4850668 LAMPS AND BALLASTS D Ballast Electronic 4 0355398 BA 4480118 0355716 BA 0355716 0447740 BA 4481278 E Fluorescent Lamp 5 Replace with like fixtures 2006 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A U S CANADA 1 800 922 1919 MEXICO 1 800 522 1900 WWW HUSSMANN COM We reserve the right to ch...

Page 2: ...8 1495 58 7 8 1495 58 7 8 1495 Width of base rail 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 1 7 8 48 Electrical Service Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 46 1 2 1181 Right end of case to center of knockout 27 686 27 686 27 686 27 686 27 686 Left end of case to center of knockout 69 1753 93 ...

Page 3: ...ure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 5 8 Estimated Charge lb 8 ft 1 7 10 ft 2 1 12 ft 2 5 14 ft 3 1 16 ft 3 7 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound NSF Certification ...

Page 4: ... 60Hz Export 0 37 0 37 0 47 0 57 0 68 84 84 108 132 156 Minimum Circuit Ampacity MCA 120V 60Hz Standard 3 97 5 27 6 90 8 53 10 17 120V 50Hz Standard 3 81 5 31 6 98 8 66 10 33 230V 60Hz Export NA NA NA NA NA 230V 50Hz Export NA NA NA NA NA 120V 60Hz Energy Efficient 2 01 2 61 3 38 4 16 4 93 230V 60Hz Energy Efficient NA NA NA NA NA Maximum Over Current Protection 120V 20 20 20 20 20 Maximum Over Cu...

Page 5: ...Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 1 3 Anti sweat Heaters BROWN BAND Fans BROWN BAND 120V POWER 1 BROWN BAND BROWN BAND HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM ...

Page 6: ... G G G G 5 Light Circuits 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers R Red G Green BL Blue B Black W White W B G R R B L B L R B L B L G G G 4 5 5 5 Optional Ledge Light Circuit Typical Shelf Ballast Wiring Maximum lamps per ballast is four 4 Different shelf config...

Reviews: