background image

rev. 0508 

9

Non-Glare Glass

The  high  optical  clarity  of  this  glass  is  possible  due  to 

special coatings on the glass surface itself. To preserve this 

coating and the optical clarity, keep the glass clean.
Water is the only solution recommended for use in cleaning 

non-glare glass. The damage to the glass from improper, 

caustic solutions is irreparable.
In addition to cleaning the glass with the recommended 

product, there are precautions that should be taken when 

working and cleaning the inside of the case.

•   When cleaning the inside of the cases, we 

recommend that the glass be fully opened and 

covered to prevent solutions from splashing onto the 

glass and ruining the coating on the inside.

Plexiglass and acrylic care

Improper cleaning not only accelerates the cleaning cycle 

but also degrades the quality of this surface. Normal daily 

buffing motions can generated static cling attracting dust 

to the surface. Incorrect cleaning agents or cleaning cloths 

can  cause  micro  scratching  of  the  surface,  causing  the 

plastic to haze over time.

cleaning

Hussmann recommends using a clean damp chamois, or a 

paper towel marked as “dust and abrasive free” with 

210

®

 

Plastic cleaner and Polish

 available by calling Sumner 

Labs at 

1-800-542-8656

. Hard, rough cloths or paper towels 

will scratch the acrylic and should not be used.

antistatic coatings

The 

210

®

  has  proven  to  be  very  effective  in  not  only 

cleaning  and  polishing  the  Plexiglass  surface,  but  also 

providing antistatic and anti-fog capabilities. This product 

also seals pores and provides a protective coating.

User information (cont'd)

Summary of Contents for Q1-DC Wedge

Page 1: ...Q1 DC Deli Service Case P N Q1 DC 0508 INSTALLATION OPERATION GUIDE CHINO Q1 DC Deli Service Case Rev 0508 Installation Operation Manual ...

Page 2: ...mendations to User Refrigerated 33 This Booklet Contains Information on Q1 DC refrigerated service deli merchandiser Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspected at our factory and the carrier has assumed responsibility for safe arrival If damaged either apparent or concealed claim must be ma...

Page 3: ...ROM FRONT TO BACK AND SIDE TO SIDE PRIOR TO JOINING A LEVEL CASE IS NECESSARY TO INSURE PROPER OPERATION WATER DRAINAGE GLASSALIGNMENT AND OPERATION OF THE HINGES SUPPORTING THE GLASS LEVELING THE CASE CORRECTLY WILL SOLVE ALL HINGE OPERATION AND GLASS PROBLEMS NOTE A To avoid removing concrete flooring begin lineup leveling from the highest point of the store floor B When wedges are involved in a...

Page 4: ...finger to smooth silicone as thin as possible at masking tape on inside and outside of rear mullion apply additional silicone if necessary Remove tape applied on line 4 11 Remove front back and end shipping braces Q1 DC Refrigerated Wedges and Standard Cases Line up taper pins and line up plates with holes on adjoining case Bolting is located at the rear of the case behind the air discharge wall a...

Page 5: ...provide means to prevent freezing The water seal should be insulated to prevent condensation Refrigeration Refrigerant Type The standard refrigerant will be R 22 unless otherwise specified on the customer order Check the serial plate on the case for information Piping The refrigerant line outlets are located under the case Locate first the electrical box the outlets are then on the same side of th...

Page 6: ...r 5 F 7 F Thermostat Location Thermostats are located in the electrical section behind the rear panel on the right hand side of the case facing the back of the case Electrical Wiring Color Code CASE MUST BE GROUNDED NOTE Refer to label affixed to case to determine the actual configuration as checked in the TYPE INSTALLED boxes Electrical Circuit Identification Standard lighting for all models will...

Page 7: ... of trim needed will depend on how much the floor is out of level NOTE The splashguard must be removable to allow access to components behind it 1 Remove all dirt wax debris etc from the area of the splashguard to ensure a secure adhesion 2 Apply a good contact cement to the trim allowing a proper dry time 3 Install trim to the splashguard so that it is flush with the floor User Information Stocki...

Page 8: ...y so that it is cool and moist when covering the product 5 Discharge air temperature should be approximately 26 F with between 150 200 FPM air velocity Do not display product directly within the air discharge 6 Clean humidity system a minimum of every 90 days for proper system operation Case Cleaning Long life and satisfactory performance of any equipment are dependent upon the care given to it To...

Page 9: ...e Plexiglass and Acrylic Care Improper cleaning not only accelerates the cleaning cycle but also degrades the quality of this surface Normal daily buffing motions can generated static cling attracting dust to the surface Incorrect cleaning agents or cleaning cloths can cause micro scratching of the surface causing the plastic to haze over time Cleaning Hussmann recommends using a clean damp chamoi...

Page 10: ...rs Hussmann recommends using 15 Sil Fos for repairs Tips and Troubleshooting Before calling for service check the following 1 Check electrical power supply to the equipment for connection 2 Check fixture loading Overstocking case will affect its proper operation 3 If frost is collecting on fixture and or product check that Humidity Control is working properly and that no outside doors or windows a...

Page 11: ...5 W1750026 Deli Curve Glass Q1 DC 6R 6 W1750007 Standard Case Q1 DC 8R 8 W1750008 Q1 DC 9R 9 W1750009 Q1 DC 10R 10 W1750009 Q1 DC 12R 12 W1750010 Q1 DC S Q1 DC 3S 3 W1750034 01 Q1 DC 4S 4 W1750034 02 Q1 DC 5S 5 W1750034 03 Q1 DC 6S 6 W1750034 04 Q1 DC 7S 7 W1750034 05 Q1 DC 8S 8 W1750034 06 Q1 DC 9S 9 W1750034 07 Q1 DC 10S 10 W1750034 08 Q1 DC 11S 11 W1750034 09 Q1 DC 12S 12 W1750034 10 ...

Page 12: ...09 21 06 D Q 115 VAC 1Ø 50 60 Hz L LIGHT SWITCH TIPPETTE 125 01 0311 CANOPY LIGHT T STAT SUCTION SOLENOID AIR SWEEP FANS COMAIR MX2B1 E1 1 125 01 2012 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 SOLENOID 225 01 3206 THERMOSTAT 225 01 0707 L1 L2 L3 N G CIRCUIT 1 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 CAP OFF WIRE M EVAP FAN MOTOR 1 0392457 M LEDGE LIGHT OPTIONAL BALLAST ...

Page 13: ...5 01 3283 SOLENOID 225 01 3206 THERMOSTAT 225 01 0707 L1 L2 L3 N G CIRCUIT 1 M M EVAP FAN MOTOR 2 0392457 M M LEDGE LIGHT OPTIONAL BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L F21T5 36 125 03 1129 F21T5 36 125 03 1129 F21T5 36 125 03 1129 F21T5 36 125 03 1129 F21T5 36 125 03 1129 F21T5 36 125 03 1129 RECPTACLE 1 125 101 0443 RJ 45 N...

Page 14: ...2012 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 SOLENOID 225 01 3206 THERMOSTAT 225 01 0707 L1 L2 L3 N G CIRCUIT 1 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 M M EVAP FAN MOTOR 2 0392457 M M LEDGE LIGHT OPTIONAL BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L RECPTACLE 1 125 101 0443 RJ 45 ...

Page 15: ... N G CIRCUIT 1 F28T5 48 125 03 1132 F28T5 48 125 03 1132 AIR SWEEP FANS 3 125 01 2012 M M EVAP FAN MOTOR 3 0392457 M M M M F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 F28T5 48 125 03 1132 CAP OFF WIRE CANOPY LIGHTS LEDGE LIGHTS OPTIONAL BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 ...

Page 16: ...LI W1750006 Q1 DC 4R REVISED BALLAST TO LH 4 ECN 10663 09 21 06 D Q 115 VAC 1Ø 50 60 Hz L LIGHT SWITCH TIPPETTE 125 01 0311 CANOPY LIGHT T STAT SUCTION SOLENOID AIR SWEEP FAN 1 125 01 2012 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 SOLENOID 225 01 3202 THERMOSTAT 225 01 0707 L1 L2 L3 N G CIRCUIT 1 F28T5 48 125 03 1132 F28T5 48 125 03 1132 M EVAP FAN MOTOR 1 0392457 M BALLAST 125 01 3267 FULHA...

Page 17: ... G CIRCUIT 1 M EVAP FAN MOTOR 2 0392457 M M BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L F35T5 60 125 03 1135 CAP OFF WIRE F35T5 60 125 03 1135 CAP OFF WIRE CAP OFF WIRE F35T5 60 125 03 1135 CAP OFF WIRE CANOPY LIGHT LEDGE LIGHT OPTIONAL DANFOSS AKS 11 164 225 01 3225 OPTIONAL SENSOR SENSOR CPC 225 01 3260 TWO MAXIMUM OPTIONAL SENSO...

Page 18: ...UCTION SOLENOID AIR SWEEP FANS 2 125 01 2012 RECPTACLE 1 125 01 0443 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 SOLENOID 225 01 3202 THERMOSTAT 225 01 0707 L1 L2 L3 N G CIRCUIT 1 BALLAST 125 01 3266 FULHAM LH3 120 L BALLAST 125 01 3266 FULHAM LH3 120 L M M EVAP FAN MOTOR 2 0392457 M M F21T5 36 125 03 1129 F21T5 36 125 03 1129 F21T5 36 125 03 1129 F21T5 36 125 03 1129 RJ 45 NETWORK JACK 125 01...

Page 19: ...OID AIR SWEEP FANS 2 125 01 2012 15 AMP FUSE 125 01 3282 FUSE HOLDER 125 01 3283 SOLENOID 225 01 3202 THERMOSTAT 225 01 0707 L1 L2 L3 N G CIRCUIT 1 F28T5 48 125 03 1132 F28T5 48 125 03 1132 M M EVAP FAN MOTOR 2 0392457 M M BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L DANFOSS AKS 11 164 225 01 3225 OPTIONAL SENSOR SENSOR CPC 225 01 3260 TWO MAXIMUM OPTIONAL SENSOR SENSO...

Page 20: ...28T5 48 125 03 1132 F28T5 48 125 03 1132 CAP OFF WIRE Q1 DC 9R Q1 DC 9R Q1 DC 10R Q1 DC 10R CANOPY LIGHT CANOPY LIGHT Q1 DC 9R LEDGE LIGHT Q1 DC 9R LEDGE LIGHT LEDGE LIGHT OPTIONAL LEDGE LIGHT OPTIONAL M M M M Q1 DC 9R Q1 DC 10R F35T5 60 125 03 1135 F35T5 60 125 03 1135 BALLAST 125 01 3267 FULHAM LH4 120 L F35T5 60 125 03 1135 F35T5 60 125 03 1135 F35T5 60 125 03 1135 F35T5 60 125 03 1135 BALLAST ...

Page 21: ...USE 125 01 3282 FUSE HOLDER 125 01 3283 SOLENOID 225 01 3202 THERMOSTAT 225 01 0707 L1 L2 L3 N G CIRCUIT 1 F28T5 48 125 03 1132 F28T5 48 125 03 1132 M M EVAP FAN MOTOR 3 0392457 M M F28T5 48 125 03 1132 F28T5 48 125 03 1132 M M BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L BALLAST 125 01 3267 FULHAM LH4 120 L DANFOSS AKS 11 164 225 01 3225 OPTIONAL SENSOR SENSOR CPC 225...

Page 22: ...6 7 8 DEFROST TIMER OMNI STAT 120V 50 60 Hz 125 01 2303 CONDENSING UNIT RLA 6 7A MCC 10 5A LRA 45 6A R C LIGHT SWITCH TIPPETTE 125 01 0311 LIGHT SWITCH TIPPETTE 125 01 0311 SWITCH MOTOR START SQ D 125 01 0271 BUNDLE PURPLE LABELED EVAP PAN CIRCUIT BUNDLE ORANGE LABELED LIGHT CIRCUIT BUNDLE BROWN LABELED FAN CIRCUIT BUNDLE BLUE LABELED CONDENSING UNIT CIRCUIT TECUMSEH HGA9430YXAXB 115VAC 60HZ 225 0...

Page 23: ... 01 2303 CONDENSING UNIT RLA 6 7A MCC 10 5A LRA 45 6A R C LIGHT SWITCH TIPPETTE 125 01 0311 LIGHT SWITCH TIPPETTE 125 01 0311 SWITCH MOTOR START SQ D 125 01 0271 BUNDLE PURPLE LABELED EVAP PAN CIRCUIT BUNDLE ORANGE LABELED LIGHT CIRCUIT BUNDLE BROWN LABELED FAN CIRCUIT BUNDLE BLUE LABELED CONDENSING UNIT CIRCUIT TECUMSEH HGA9430YXAXB 115VAC 60HZ 225 03 0100 FISHER EVAPOWAY DM15WW1D OPTIONAL 1500W ...

Page 24: ... CONDENSING UNIT CIRCUIT TECUMSEH HGA9430YXAXB 115VAC 60HZ 225 03 0100 FISHER EVAPOWAY DM15WW1D OPTIONAL 1500W 120 VAC 12 5A 125 01 0765 OPTIONAL M M CAP OFF WIRE M DANFOSS AKS 11 164 225 01 3225 OPTIONAL SENSOR SENSOR CPC 225 01 3260 TWO MAXIMUM OPTIONAL SENSOR SENSOR COMTROL 90TB002G01 225 01 2028 OPTIONAL SENSOR RJ 45 NETWORK JACK 125 01 0200 125 01 0202 CIRCUI T 2 120 VAC 1Ø 60 Hz CIRCUIT 2 NO...

Page 25: ...T SWITCH TIPPETTE 125 01 0311 LIGHT SWITCH TIPPETTE 125 01 0311 SWITCH MOTOR START SQ D 125 01 0271 BUNDLE ORANGE LABELED LIGHT CIRCUIT BUNDLE BROWN LABELED FAN CIRCUIT BUNDLE BLUE LABELED CONDENSING UNIT CIRCUIT TECUMSEH HGA9430YXAXB 115VAC 60HZ 225 03 0100 FISHER EVAPOWAY DM15WW1D OPTIONAL 1500W 120 VAC 12 5A 125 01 0765 OPTIONAL SENSOR SENSOR CPC 225 01 3260 TWO MAXIMUM RJ 45 NETWORK JACK 125 0...

Page 26: ...NGE LABELED LIGHT CIRCUIT BUNDLE BROWN LABELED FAN CIRCUIT BUNDLE BLUE LABELED CONDENSING UNIT CIRCUIT TECUMSEH HGA9443YXAXB 115VAC 60HZ 225 03 0104 FISHER EVAPOWAY DM15WW1D OPTIONAL 1500W 120 VAC 12 5A 125 01 0765 OPTIONAL SENSOR SENSOR CPC 225 01 3260 OPTIONAL M M CAP OFF WIRE NOTE CASE MUST BE GROUNDED CANOPY LIGHT F21T5 36 125 03 1129 F21T5 36 125 03 1129 BALLAST 125 01 3267 FULHAM LH4 120 L L...

Page 27: ...ITCH TIPPETTE 125 01 0311 LIGHT SWITCH TIPPETTE 125 01 0311 SWITCH MOTOR START SQ D 125 01 0271 BUNDLE ORANGE LABELED LIGHT CIRCUIT BUNDLE BROWN LABELED FAN CIRCUIT BUNDLE BLUE LABELED CONDENSING UNIT CIRCUIT TECUMSEH HGA9443YXAXB 115VAC 60HZ 225 03 0104 FISHER EVAPOWAY DM15WW1D OPTIONAL 1500W 120 VAC 12 5A 125 01 0765 OPTIONAL SENSOR SENSOR CPC 225 01 3260 TWO MAXIMUM RJ 45 NETWORK JACK 125 01 02...

Page 28: ...PTIONAL SENSOR SENSOR CPC 225 01 3260 TWO MAXIMUM RJ 45 NETWORK JACK 125 01 0200 125 01 0202 CIRCUI T 2 120 VAC 1Ø 60 Hz CIRCUIT 2 NOTE CASE MUST BE GROUNDED 15 0 L1 L2 L3 120 V LOADING OPTIONAL SCALE STAND GFCI DUPLEX 125 01 3178 W G BK OPTIONAL M M DANFOSS AKS 11 164 225 01 3225 OPTIONAL SENSOR SENSOR COMTROL 90TB002G01 225 01 2028 OPTIONAL SENSOR M LEDGE LIGHT OPTIONAL CAP OFF WIRE CAP OFF WIRE...

Page 29: ... 0765A OPTIONAL SENSOR SENSOR CPC 225 01 3260 TWO MAXIMUM RJ 45 NETWORK JACK 125 01 0200 125 01 0202 CIRCUI T 2 120 VAC 1Ø 60 Hz CIRCUIT 2 NOTE CASE MUST BE GROUNDED 15 0 L1 L2 L3 120 V LOADING OPTIONAL SCALE STAND GFCI DUPLEX 125 01 3178 OPTIONAL M M DANFOSS AKS 11 164 225 01 3225 OPTIONAL SENSOR SENSOR COMTROL 90TB002G01 225 01 2028 OPTIONAL SENSOR M BALLAST 125 01 3267 FULHAM LH4 120 L F35T5 60...

Page 30: ... UNIT CIRCUIT TECUMSEH HGA9462ZXDXM 115VAC 60HZ 225 03 0101 FISHER EVAPOWAY DM15WW 3D OPTIONAL 1500W 240 VAC 6 25A 125 01 0765A OPTIONAL SENSOR SENSOR CPC 225 01 3260 OPTIONAL M M CAP OFF WIRE NOTE CASE MUST BE GROUNDED CANOPY LIGHT F21T5 36 125 03 1129 F21T5 36 125 03 1129 BALLAST 125 01 3267 FULHAM LH4 120 L LEDGE LIGHT OPTIONAL F21T5 36 125 03 1129 BALLAST 125 01 3266 FULHAM LH3 120 L CAP OFF W...

Page 31: ...NIT CIRCUIT TECUMSEH HGA9462ZXDXM 208VAC 60HZ 225 03 0101 FISHER EVAPOWAY DM15WW 3D OPTIONAL 1500W 240 VAC 6 25A 125 01 0765A TWO MAXIMUM RJ 45 NETWORK JACK 125 01 0200 125 01 0202 CIRCUI T 2 120 VAC 1Ø 60 Hz CIRCUIT 2 NOTE CASE MUST BE GROUNDED 15 0 L1 L2 L3 120 V LOADING OPTIONAL SCALE STAND GFCI DUPLEX 125 01 3178 W G BK OPTIONAL M M M BALLAST 125 01 3267 FULHAM LH4 120 L L1 N L1 L2 L1 N L1 L2 ...

Page 32: ...ller should perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant according to manufacturer s recommendations b Observation of outside influences such as drafts radiant heating from the ceiling and from lamps Such influence should be properly corrected ...

Page 33: ...n loaded with warm product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air flow and mixing with room air 6 Are spotlights or other high intensity lighting directed onto the product 7 Are there unusual draft conditions from heating air conditioning ducts open doors etc 8 Is ...

Page 34: ...d prolonged temperature recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising products to ensure that potentially hazardous vegetable products are not placed in non refrigerated areas e Display and storage equipment doors should be kept closed during periods of inactivity f Minimize the t...

Page 35: ...___________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________________________ _______________ ...