background image

8 of 9

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P4NX-E 

Technical Data Sheet

4 ft case

6 ft or 8 ft case

12 ft case

R

BL

R

BL

7

7

R

BL

6

B

W

W

BL

R

G

Connector

Connector

B

W

B

W

B

W

R

BL

R

BL

7

7

R

BL

R

BL

R

BL

7

7

R

BL

R

BL

BL

BL

(TYP)

Shelf Light

Plug & Receptacle

 

 

R = Red          G = Green          BL = Blue          B = Black          W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

Optional Shelf Harness and LED Light Circuits for 
 
 
Two Rows of Shelves

R

R

B

Optional Shelf Lighting
LED Fixtures

Summary of Contents for P4NX-E

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part D...

Page 2: ...legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 E...

Page 3: ...745 Add 10 Btu hr ft per shelf row for LED fixtures Add 20 Btu hr ft per shelf row for fluorescent lamps DEFROST DATA P4NX E Frequency hr 6 Defrost Water lb ft day 8 15 based on case configuration and...

Page 4: ...35 0 40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optio...

Page 5: ...Display Area 3 Sq Ft Ft 4 28 ft2 ft 1 30 m2 m Shelf Area 4 Sq Ft Ft 6 46 ft2 ft 1 97 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerat...

Page 6: ...Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R B 4 ft 6 f...

Page 7: ...G All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Four Rows of Shelve...

Page 8: ...7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground an...

Page 9: ...L R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Reviews: