3 of 9

P/N 0476944_B

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

1

/

(38)

12 

3

/

(323)

Refrigeration 

Outlet

Electrical 

Case to Case 

Connections

11 

7

/

(301)

FAN


L

3 In. 

(77 mm) 

Required 

Air Gap

74 

3

/

8

 

(1890)

14 

3

/

(365)

3

/

4  

(120)

48

 

(1220)

28 

5

/

8

 

(727)

16  

1

/

(413)

34 

5

/

8

 

(880)

44 

3

/

4

 

(1136)

41 

1

/

2

 

 

(1054)

15

 

(381)

P2XRO-E

31

 

(788)

56 

1

/

(1435)

41

 

(1041)

18 

7

/

8

 

(479)

46 

1

/

(1174)

40 

5

/

(1032)

31 

3

/

(806)

44 

5

/

(1133)

1

/

4

 

(183)

REFRIGERATION DATA

Note:

This data is based on store temperature and

humidity that does not exceed 75°F and 55% R.H.

P2XRO-E

Discharge Air °F

33

Evaporator °F

24

Unit Sizing °F

22

Btu/hr/ft — Unlit Shelves

P2XRO-E

‡‡

Parallel

Conventional

U

NLIT

970

1050

‡‡ Add 10 Btu/hr/ft 

per shelf row

for LED fixtures.

Add 20 Btu/hr/ft 

per shelf row

for fluorescent lamps.

DEFROST DATA

P2XRO-E

Frequency (hr)

8

Defrost Water (lb/ft/day)

6

(±15% based on case configuration and

product loading.

O

FFTIME

P2XRO-E

Temp Term °F

48°F

Failsafe Minutes

30

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise: close 48°F – open 33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control

P2XRO-E

CI/CO*

17/7°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to determine

PSIG conversions.

Estimated Charge (lbs)**

P2XRO-E

4 ft

1.2

6 ft

1.7

8 ft

2.3

12 ft

3.3

**This is an average for all refrigerant types actual

refrigerant charge may vary by approximately half

a pound.

Impact  

Excel

P2XRO-E

All Produce

Multi-deck, 2 Display Levels

Dimensions shown as inches and (mm).

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.

Summary of Contents for P2XRO-E

Page 1: ...andard Fan Assembly 1 0392457 Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 Item Part Description Wiring Item B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744 C Optional Adjustable Refrigeration Thermostat 3 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY D Ballast E...

Page 2: ...50 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of stub up area 38 1 2 978 38 1 2 978 38 1 2 978 38 1 2 978 ...

Page 3: ...hr ft per shelf row for fluorescent lamps DEFROST DATA P2XRO E Frequency hr 8 Defrost Water lb ft day 6 15 based on case configuration and product loading OFFTIME P2XRO E Temp Term F 48 F Failsafe Minutes 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control P2XRO E CI CO 17 7 F Indoor Unit Only Pressure ...

Page 4: ... 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Additional 2 Row Canopy 0 51 1 02 1 02 1 54 59 118 118 170 Additional 3 Row Canopy 0 77 1 ...

Page 5: ...l Display Area 3 Sq Ft Ft 3 92 ft2 ft 1 19 m2 m Shelf Area 4 Sq Ft Ft 6 59 ft2 ft 2 01 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Length ft m 4 Shelf s...

Page 6: ...al Two Row Canopy Optional Three Row Canopy Connector 5 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band 3 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R B 4 ft 6 ft or 8 ft 12 ft 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser mu...

Page 7: ...L FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Two Rows of Shelves 4 ft case Connector 5 4 5 B W Connector 6 ft or 8 ft case 12 ft case R R W BL BL R B BL BL R 5 4 5 B W R R W BL BL R B BL BL R Optional Shelf Lighting Fluorescent Fixtures ...

Page 8: ...L 7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixture...

Page 9: ...BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND W Connector Optional Shelf Harness and LED Light Circuits for 3...

Reviews: