background image

2 of 6

P2EP

LUS

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Electrical

Refrigeration

72 

1

/

4

 (1835)

1

/

8

 (105)

24 

1

/

8

 (613)

1

/

2

 (140)

3

/

8

 (35)

1

/

2

 (114)

29 

1

/

2

(749)

35 

1

/

8

(891)

46 

1

/

4

(

1174)

9

(230)

30 

5

/

8

(778)

27 

1

/

2

(699)

40 

5

/

8

(1032)

4 (102)

Water Seal

(See Note*)

Waste Outlet

4

 

(102)

40 

5

/

8

(1032)

30 

1

/

2

(775)

96 

3

/

8

 (2448)

88 

3

/

8

 (2245)

Dimensions shown as inches and (mm).

8 Ft

12 ft

General

Length of Case 

(without ends or partitions)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum outside dimensions of case back to front 

(includes bumper)

46 

1

/

4

(1174)

46 

1

/

4

(1174)

Back of case to front of splashguard

35 

1

/

(891)

35 

1

/

(891)

Back of case to outside edge of front skidrail

29 

1

/

(749)

29 

1

/

(749)

Width of skidrail

1

/

(114)

1

/

(114)

Right end of case to outside edge of external support

1

/

(140)

1

/

(140)

Distance between inside edges of external support and center support

40 

5

/

(1032)

40 

5

/

(1032)

Distance between inside edges of center supports

NA

44 (1118)

Width of external support

1

/

(105)

1

/

(105)

Stub-up area between front skidrail and splashguard

4 (102)

4 (102)

Right edge of case (excluding end) to inside edge of external support

3

/

(35)

3

/

(35)

Electrical Service

Right end of case to center of farthest knockout

88 

3

/

(2245)

136 

1

/

(3467)

Back outside of case to center of knockout

30 

1

/

(775)

30 

1

/

(775)

Length of electrical raceway

34 

1

/

(876)

34 

1

/

(876)

Waste Outlet

Right end of case to center of waste outlet

24 

1

/

(613)

72 

1

/

(1835)

Left end of case to center of waste outlet

72 

1

/

(1835)

72 

1

/

(1835)

Back outside of case to center of waste outlet

27 

1

/

(699)

27 

1

/

(699)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Outside diameter of drip pipe

1

/

(38)

1

/

(38)

*

Note:

Water seal outlet must clear front skid rail.

Refrigeration Outlet

Right end of case to center of refrigeration outlet

9 (230)

9 (230)

Back outside of case to center of refrigeration outlet

30 

5

/

(778)

30 

5

/

(778)

Engineering

Plan Views

Produce

12-2003

Summary of Contents for P2EP

Page 1: ...80 Fan Blade embossing toward motor B 0137880 Optional Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS C 0428648 Ballast 2 lamps 3 0428649 Ballast 3 lamps 3 D Fluorescent Lamp 4 Replace with like fixtures We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do not entitle th...

Page 2: ... 40 5 8 1032 Distance between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of case to center of knoc...

Page 3: ...ONE Defrost Water lb ft day 6 15 based on case configuration and product loading OFFTIME P2EPLUS Time minutes NONE ELECTRIC OR GAS Not Recommended CONVENTIONALCONTROLS Low Pressure Backup Control P2EPLUS CI CO 27 F 17 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Liquid Line in 3 8 S...

Page 4: ...t 120V 60Hz 0 52 0 78 36 54 Export 230V 50Hz 0 56 0 84 88 132 Constant on Anti sweat Heaters NA Cycling Anti sweat Heaters NA Min Circuit Ampacity With Standard Fans 120V 60Hz 1 20 1 70 Export 230V 50Hz 0 76 1 04 With Energy Efficient Fans 120V 60Hz 0 72 0 98 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost...

Page 5: ...k W White 120V POWER 120V NEUTRAL FIELD GROUND CASE GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light...

Page 6: ...L Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 3 R 4 4 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 3 4 4 120V NEUTRAL ORANGE OR TAN BAND Light Switch 120V POWER ORANGE OR TAN BAND B ...

Reviews: