MWG
Data Sheet
4 of 4
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact
MWG
Meat / Delicatessen
Electrical Data
6 ft
8 ft
12 ft
Number of Fans –9W
1
2
3
Amperes
Watts
Merchandiser
6 ft
8 ft
12 ft
6 ft
8 ft
12 ft
Fans
Standard (120V 60Hz)
0.77
1.54
2.31
62
124
186
Export (230V 50Hz)
0.47
0.94
1.41
70
140
210
Energy Efficient (120V 60Hz)
0.38
0.76
1.14
25
50
75
Constant on Anti-sweat Heaters
NA
Cycling Anti-sweat Heaters
NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz)
0.97
1.74
2.51
Export (230V 50Hz)
0.67
1.14
1.61
With Energy Efficient Fans (120V 60Hz)
0.58
0.96
1.34
Maximum Over Current Protection (120V)
20
20
20
Maximum Over Current Protection (230V)
15
15
15
Supplemental Gas Heaters
NA
208V 1
Φ
Φ
Electric Defrost
NA
Standard Lighting
Optional Lighting
Optional Shelf Lighting
None
None
None
Refrigeration
Thermostat
2
To
Condensing
Unit
}
Light Blue
= 120V P
OWER
= 120V N
EUTRAL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
C
IRCLED
NUMBERS
= P
ARTS
L
IST
I
TEM
N
UMBERS
Fan Wiring
Offtime Defrost
1, 2 & 3 Fans
120V N
EUTRAL
B
ROWN
B
AND
120V P
OWER
Fans
1
B
ROWN
B
AND
6 ft
8 ft
12 ft