background image

P/N 0486351_B

9 of 9

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

6

6

6

6

6

6

6

R

BL

5

B

B

W

W

BL

R

G

4 ft case

6 ft or 8 ft case

12 ft case

(TYP)

Shelf Light

Plug & Receptacle

B

Connector

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

6

6

6

6

6

6

6

R

BL

5

B

B

W

W

BL

R

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

R

BL

6

6

6

6

6

6

6

R

BL

5

B

B

W

W

BL

R

 

 

R = Red          G = Green          BL = Blue          B = Black          W = White

=  120V P

OWER

=  120V N

EUTRAL

=  F

IELD

 G

ROUND

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

=  C

ASE

 G

ROUND

W

Connector

Optional Shelf Harness and LED Light Circuits for 
 
 
3, 4, 5, 6 & 7 Rows of Shelves

Optional Shelf Lighting

LED Fixtures

Summary of Contents for M3NX-GEP

Page 1: ...4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO4410102 0461805 Fan Blade FB 4780446 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0461805 F...

Page 2: ...54 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection poin...

Page 3: ...to determine PSIG conversions Estimated Charge lb M3NX GEP 4 ft 1 6 6 ft 2 2 8 ft 3 1 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a...

Page 4: ...ent 0 35 0 40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85...

Page 5: ...otal Display Area 3 Sq Ft Ft 3 37 ft2 ft 1 03 m2 m Shelf Area 4 Sq Ft Ft 4 60 ft2 ft 1 40 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refri...

Page 6: ...NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND 4 4 3 3 3 4 4 4 4 4 4 Optional Two Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange...

Page 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Page 8: ...L 6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground a...

Page 9: ...L R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 6 6 6 6 6 6 6 R BL 5 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...