REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75°F and
55% R.H. Schedule defrost at night while
lights are off.
SMGT
Discharge Air (°F)
24
Evaporator (°F)
18
Unit Sizing (°F)
16
Btu/hr/ft*
SMGT
Parallel
420
Conventional
450
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
SMGT
Frequency (hr)
24
Defrost Water (lb/ft/day)
0.17
(± 15% based on case configuration and
product loading).
SMGT
O
FFTIME
(minutes)
70
Failsafe (minutes)
90
E
LECTRIC OR
G
AS
Not Recommended
CONVENTIONALCONTROLS
Low Pressure Backup Control
SMGT
CI/CO (Temp °F)**
11°F / 1°F
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)**
Not Recommended
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
1
/
2
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
5
/
8
Estimated Charge (lb)***
4 ft
0.75
6 ft
1.0
8 ft
1.5
12 ft
2.0
***This is an average for all refrigerant
types. Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by:
Each Plastic End w/ Bumper (in.)
3
1
/
2
Each End/Partition (in.)
1
1
/
2
3 of 6
P/N 0420064A
7
( 1 7 8 )
10
( 2 5 4 )
24
O
F A N
SMGT
52
( 1 3 2 1 )
33
5/
8
(854)
22
1
/
2
(572)
25
5/8 (651)
28
3
/
4
(730)
34
( 8 6 4 )
20
( 5 0 8 )
24
1/
4
(616)
13
3/
4
(349)
33
3
/
8
(849)
44
5
/
8
(1133)
3
5/
8
(92)
11
3
/8
( 2 8 9 )
10
1
/2
( 2 6 7 )
Refrig.
Outlet
Elec.
FA
N
C
O
I
L
C O I L
Dimensions shown as in. and (mm).
Flat Hinged Glass, Gravity with Blower assist, 3 Display Level
Impact
SMGT
Meat / Delicatessen
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation
Foundation (NSF
®
) Standard #7 requirements.
NOTES:
• The bumper is 4 in. (102 mm) wide. Center of the bumper is 18
1
/
2
in.
(470 mm) from the floor.