RLNIE with
Innovator Doors
Technical Data Sheet
6 of 10
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Defrost Termination
Thermostat
Refrigeration
Thermostat
(Optional)
Pink
2
3
}
To
Condensing
Unit
Terminal Blocks in End Raceway
Low Temperature with
Electric Defrost
20
21
22
26
17
1
2
3
4
5
6
7
8
10
11
14
13
16
LIGHTS
(120V)
DEFROST HEATERS
(208V)
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
THESE ARE MARKER COLORS (WIRE MAY VARY.)
CAUTION:
When multiplexing
merchandisers equipped with defrost
heaters, if branch circuit overcurrent
protection is larger than the
individual merchandiser’s defrost
circuit load, then additional
supplemental overcurrent protection
may be required per NEC Articles
210 and 240.
R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue B = Black
BR =Brown Y =Yellow OR = Orange W = White
Fan and Heater Circuits - Electric Defrost (standard)
RLNIE End Compartment
24
25
12
FANS & A.S.
(120V)
LIGHTS
(Neutral)
FANS & A.S. (Neutral)
Permanent Internal
Jumpers
R
P
W
BR
OR
R
R
R
B
B
R
R
B
P
2P
B
B
OR
B
2P
Y
Removable External
Jumpers
Dark Blue
Refer to
Innovator Reach-In
Glass Door, Installation and
Service
manual, P/N 0425683,
for
Innovator
door and frame
replacement parts.
Rear Defrost
Front Defrost
Defrost Limit
O.O.R.
1
2
3
8
7
6
4
5
Fan Relay Coil
208V
F
208V
R
R
R
1
3
7
R
B
B
4
R
R
8
8
Fans
COM
NC
NO
F
F
Fan Relay
Relay Control
C.O.R.
A.S. Relay Coil
14
16
24
25
26
NC
AS
A.S. Relay
Frame A.S.
Door A.S.
13
10
11
12
22
21
AS
120V
Neutral
Reheater
B
B
7
7
1
5
6
BR
W
3
1
B
B
P
2P
6
P
2P
Switch
L
Lights
Defrost Termination Thermostat
FIELD WIRED
17
20
C.O.R.
120V
NEUTRAL
DB
DB
OR
OR
10
End Compartment Connects to Main Terminal Block at Rear (see Page 7).