3 of 6
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P/N 0378424B
C
O
I
L
P2
38
1
/
8
(969)
7
1
/
2
(152)
30
1/
2
(774)
3
1
/
8
(079)
39
1
/
2
(1002)
42
1
/
2
(1079)
74
(1878)
27
1
/
2
(699)
29
1
/
2
(749)
35
(891)
46
1
/
2
(1174)
30
1
/
4
(770)
25
1
/
2
(647)
17
3
/
8
(441)
REFRIGERATION DATA
Note:
This data is based on store
temperature and humidity that does not
exceed 75°F and 55% R.H.
P2
P2E
Discharge Air °F
37
33
Evaporator °F
21
24
Unit Sizing °F
19
22
Btu/hr/ft**
P2
P2E
Parallel
1015
970
Conventional
1090
1050
**For all refrigeration equipment other than
Husssmann, use conventional BTU values.
DEFROST DATA
P2
P2E
Frequency (hr)
6
8
Defrost Water (lb/ft/day)
6
6
(±15% based on case configuration and
product loading.
O
FFTIME
P2
P2E
Temp Term °F
48°F
48°F
Failsafe Minutes
30
30
E
LECTRIC OR
G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONALCONTROLS
Low Pressure Backup Control
P2
P2E
CI/CO**
14/4°F 17/7°F
Indoor Unit Only, Pressure Defrost
Termination**
48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
1
/
2
Liquid Line (in.)
3
/
8
Suction Line (in.)
7
/
8
Estimated Charge (lbs)***
P2
P2E
8 ft
1.5
2.3
12 ft
2.0
3.3
***This is an average for all refrigerant types
actual refrigerant charge may vary by
approximately half a pound.
Length (in.) Added to Lineup
by Each End or Insulated
Partition
1
1
/
2
Impact
P2
Bulk Produce
Single Deck, 1 Display Level
Dimensions shown as inches and (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF ®) Standard #7 requirements.