4 of 4
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
P1 Data Sheet
Impact
P1
Bulk Produce
Electrical Data
8 ft
12 ft
Number of Fans — 4W
2
3
Amperes
Watts
8 ft
12 ft
8 ft
12 ft
Merchandiser
Fans
Standard (120V 60Hz)
0.62
0.93
72
120
Export (230V 50Hz)
0.36
0.54
54
81
Energy Efficient (120V 60Hz)
0.28
0.42
20
30
Constant on Anti-sweat Heaters
NA
Cycling Anti-sweat Heaters
NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz)
0.82
1.13
Export (230V 50Hz)
0.56
0.74
With Energy Efficient Fans (120V 60Hz)
0.48
0.62
Maximum Over Current Protection 120V
20
20
Supplemental Gas Heaters
NA
208V 1
Φ
Φ
Electric Defrost
NA
Standard Lighting
None
Optional Lighting
None
Optional Shelf Lighting
None
Defrost
Termination
Thermostat
2
To
Condensing
Unit
}
Dark Blue
= 120V P
OWER
= 120V N
EUTRAL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
C
IRCLED
NUMBERS
= P
ARTS
L
IST
I
TEM
N
UMBERS
G
RAYED
C
OMPONENTS
I
N
12
F
OOT
M
ODELS
O
NLY.
Fan Wiring
Offtime Defrost
2 & 3 Fans
120V N
EUTRAL
B
ROWN
B
AND
120V P
OWER
Fans
1
B
ROWN
B
AND
Light Blue
3
Refrigeration
Thermostat