background image

4 of 6

M4G Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Impact  

M4G

Meat and Delicatessen

Electrical Data

8 Ft

12 Ft

Number of Fans — 9W

4

6

Amperes

Watts

Merchandiser

8 Ft

12 Ft

8 Ft

12 Ft

Fans

Standard (120V 60Hz)

2.80

4.20

220

330

Export (230V 50Hz)

1.52

2.28

228

342

Energy Efficient (120V 60Hz)

1.52

2.28

100

150

Constant on Anti-sweat Heaters

NA

Cycling Anti-sweat Heaters

NA

Min. Circuit Ampacity

With Standard Fans (120V 60Hz)

3.00

4.40

Export (230V 50Hz)

1.72

2.48

With Energy Efficient Fans (120V 60Hz)

1.72

2.48

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V

15

15

Supplemental Gas Heaters

NA

208V 1

Φ

Φ

Electric Defrost

NA

Standard Lighting
1 Row Canopy

0.51

0.77

59

85

Optional Lighting
1 Row Canopy and 1 Rail

1.02

1.54

118

170

2 Row Canopy

1.02

1.54

118

170

2 Row Canopy and 1 Row Rail

1.53

2.31

177

255

3 Row Canopy

1.53

2.31

177

255

3 Row Canopy and 1 Rail

2.04

3.08

236

340

Optional Shelf Lighting
1 Row of Shelves

0.51

0.77

59

85

2 Rows of Shelves

1.02

1.54

118

170

3 Rows of Shelves

1.53

2.31

177

255

Summary of Contents for IMPACT M4G

Page 1: ...motor B 0411744 Standard Non adjustable 2 Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Note Changed items have been underlined Merchandisers B D C D A E M4G Data Sheet Set P N 0378420C NSF Certified December 2003 Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with...

Page 2: ...ce between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Electrical Field Wiring connection point B Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside o...

Page 3: ...ion and product loading OFFTIME M4G M4GE Temp Term F 48 F 48 F Failsafe Minutes 30 35 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure Backup Control M4G M4GE CI CO 12 2 F 14 4 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser ...

Page 4: ...ans 120V 60Hz 3 00 4 40 Export 230V 50Hz 1 72 2 48 With Energy Efficient Fans 120V 60Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Row Canopy 1 02 1 54 118 170 2 Row Canopy and 1 R...

Page 5: ...ector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All component...

Page 6: ... models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch...

Reviews: