background image

8 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

96 

3

/

8

(2448)

144 

1

/

2

(3670)

Maximum outside dimension of case back to front 

(includes bumper)

46 

1

/

2

(1180)

46 

1

/

2

(1180)

Back of case to front of splash guard

35 

1

/

4

(897)

35 

1

/

4

(897)

Back of case to outside edge of front skid rail

29 

1

/

2

(747)

29 

1

/

2

(747)

Width of skid rail

1

/

2

(114)

1

/

2

(114)

Right hand end of case to inside edge of external support

1

/

2

(140)

1

/

2

(140)

Distance between edges of external support and center support

40 

5

/

8

(1032)

40 

5

/

8

(1032)

Distance between edges of center supports

NA

44 (1118)

Stub-up area between front skid rail and splash guard

4 (102)

4 (102)

Electrical Service                         

(Electrical Field Wiring connection point)

(B)

Right hand end of case to center of farthest knockout

88 

3

/

8

(2245)

136 

1

/

2

(3467) 

Back outside of case to center of knockout

30 

1

/

2

(775)

30 

1

/

2

(775)

Length of electrical raceway

34 

1

/

2

(778)

34 

1

/

2

(778)

Waste Outlet

(C)

Left hand end of case to the center of waste outlet

72 

1

/

4

(1835)

72 

1

/

4

(1835)

(D)

Right hand end of case to the center of waste outlet

24 

1

/

8

(613)

72 

1

/

4

(1835)

Back outside of case to center of waste outlet

27 

1

/

2

(699)

27 

1

/

2

(699)

Water Seal

Edge of water seal to center of waste outlet

4 (102)

4 (102)

Outside diameter of the drip pipe

1

/

(38)

1

/

(38)

*

Note:

Water seal outlet must clear front skid rail.

Refrigeration Outlet

Back of case to center of refrigeration outlet

30 

5

/

(778)

30 

5

/

(778)

Right-hand end of case to center of refrigeration outlet

9 (230)

9 (230)

2 of 7

Engineering

Electrical

Refrigeration

C

1

/

8

 (105)

D

1

/

2

 (140)

3

/

8

 (35)

1

/

2

 (114)

29 

1

/

2

(749)

35 

1

/

8

(891)

46 

1

/

4

(

1174)

9

(230)

30 

5

/

8

(778)

27 

1

/

2

(699)

40 

5

/

8

(1032)

4 (102)

Water Seal

(See Note*)

Waste Outlet

4

 

(102)

40 

5

/

8

(1032)

30 

1

/

2

(775)

A

B

Front

Dimensions shown as inches and (mm).

M3 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Meat and Produce

09-2003

Summary of Contents for Impact M3

Page 1: ...0047000 Fan Motor Evaporator 0315470 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Descrip...

Page 2: ...ut 30 1 2 775 30 1 2 775 Length of electrical raceway 34 1 2 778 34 1 2 778 Waste Outlet C Left hand end of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 D Right hand end of case to the c...

Page 3: ...M3E Parallel 1120 1055 Conventional 1205 1155 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA M3 M3E Frequency hr 6 6 Defrost Water lb ft day 7 7 15 based...

Page 4: ...z 0 96 1 34 With Export Fans 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59...

Page 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Page 6: ...120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 R R R Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER...

Page 7: ...he shelf configuration of this merchandiser is critical 2 Shelf Configuration for M3 M3E Top shelf must be 16 inches wide and placed at a 0 angle Second shelf may be either 16 or 18 inches wide and it...