Hussmann Impact Excel M3X-GEP Technical Data Sheet Download Page 3

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

M3X-GEP

U

NLIT

L

IT

Discharge Air °F

31

29

Evaporator °F

28

26

Unit Sizing °F

26

24

Btu/hr/ft — Unlit Shelves

M3X-GEP

‡‡

Parallel

Conventional

U

NLIT

810

885

‡‡ Add 10 Btu/hr/ft 

per shelf row

for LED fixtures.

Add 20 Btu/hr/ft 

per shelf row

for fluorescent lamps.

DEFROST DATA

Frequency Hrs

6

Defrost Water (lb/ft/day)

8

(± 15% 

based on case configuration and 

product loading).

O

FFTIME

M3X-GEP

Time (minutes)

35

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

M3X-GEP

19°F / 9°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to 

determine PSIG conversions.

Estimated Charge (lb)**

M3X-GEP

4 ft

1.6

6 ft

2.2

8 ft

3.1

12 ft

4.5

**This is an average for all refrigerant types.

Actual refrigerant charge may vary by 

approximately half a pound.

P/N 0463876_D

3 of 8

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

30

 

(762)

74 

3

/

8

 

(1890)

31 

5

/

(804)

3

/

(120)

30 

1

/

4   

(768)

42 

 

(1064)

33 

1

/

(851)

26 

1

/

(665)

Refrigeration 

Outlet

42 

1

/

2

 

 

(1080)

34 

5

/

8

 

(878)

FAN

L

28 

5

/

8

 

(727)

3 In. 

(77 mm) 

Required 

Air Gap

1

/

(183)

38 

1

/

4

 

(972)

15

 

(381)

Electrical 

Case to Case 

Connections

17 

1

/

(436)

29 

3

/

8

 

(746)

16 

1

/

4

 

(413)

1

/

4  

(184)

Dimensions shown as inches and (mm).

Multi-deck, 3 Display Levels, and Glass Front

Impact  

Excel

M3X-GEP

Meat, Delicatessen 

Pre-cut and Packaged Produce

M3X-GEP

NSF Certification

This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for con-
struction, materials & cleanability.

Summary of Contents for Impact Excel M3X-GEP

Page 1: ... 4780446 6 Ft Only A 7W Standard Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part Description Wiring Item THERMOSTATS B Optional Adjustable Refrigeration Thermostat 2 LAMPS BALLASTS LED FIXTURES AND POWER SUPPLY C Ballast Electronic 3 0480130 2 lamps ...

Page 2: ...of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2 3 4 70 Electrical Service Electrical Field Wiring connection point B RH End of case to center of stub up area 36 1 4 921 60 1 4 1530 84 1 4 2140 132 3 8 3363 Back of case to center of stub up area ...

Page 3: ...ermine PSIG conversions Estimated Charge lb M3X GEP 4 ft 1 6 6 ft 2 2 8 ft 3 1 12 ft 4 5 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound P N 0463876_D 3 of 8 HUSSMANN CORPORATION BRIDGETON MO 63044 2483 U S A WWW HUSSMANN COM 30 762 74 3 8 1890 31 5 8 804 4 3 4 120 30 1 4 768 42 1064 33 1 2 851 26 1 4 665 Refrigeration Outlet 42 1 2 108...

Page 4: ...0 86 1 19 230V 50Hz Export 0 58 0 76 0 96 1 34 120V 60Hz Energy Efficient 0 50 0 58 0 80 1 10 230V 60Hz Energy Efficient 0 35 0 40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Standard Lighting T 8 fluorescent 1 Row Canopy 0 26 0 51 0 51 0 77 30 59 59 85 Optional Lighting T 8 fluorescent Additional 1 Row Canopy 0 26 0 51 0 51 0 77 30 5...

Page 5: ...0 56 m3 m ARI Total Display Area 3 Sq Ft Ft 3 49 ft2 ft 1 06 m2 m Shelf Area 4 Sq Ft Ft 5 35 ft2 ft 1 63 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Refrigerated Volume less shelving and other unusable space Refrigerated Volume Unit of Length ft3 ft m3 m 3 Computed using ARI 1200 standard methodology Total Display Area ft2 m2 Unit of Len...

Page 6: ...S CASE GROUND 4 4 3 3 3 4 4 4 4 4 4 Optional Two Row Canopy Optional Three Row Canopy Connector 4 BL W BL W G R BL W B R R R BL BL R BL R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 3 Row Canopy B 4 ft 6 ft or 8 ft 12 ft Refrigeration Thermostat 2 To Condensing Unit Light Blue 1 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN B...

Page 7: ...L FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Two Rows of Shelves 4 ft case Connector 4 3 4 B W Connector 6 ft or 8 ft case 12 ft case R R W BL BL R B BL BL R 4 3 4 B W R R W BL BL R B BL BL R Optional Shelf Lighting Fluorescent Fixtures ...

Page 8: ...L 6 6 R BL R BL R BL 6 6 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and LED Light Circuits for Two Rows of Shelves R R B Optional Shelf Lighting LED Fixture...