Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans—12W

1

2

3

Number of Fans—7W

2

Amperes

Watts

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Evaporator Fan

120V

60Hz

Standard

0.65

1.00

1.30

1.95

50

78

100

150

120V

50Hz

Standard

0.75

1.10

1.50

2.25

57

84

114

171

230V

60Hz

Export

0.33

0.50

0.66

0.99

50

78

100

150

230V

50Hz

Export

0.38

0.56

0.76

1.14

57

84

114

171

120V

60Hz

Energy Efficient

0.30

0.38

0.60

0.90

18

28

36

54

230V

60Hz

Energy Efficient

0.15

0.20

0.30

0.45

18

28

36

54

Minimum Circuit Ampacity

120V

60Hz

Standard

0.85

1.20

1.50

2.15

120V

50Hz

Standard

0.95

1.30

1.70

2.45

230V

60Hz

Export

0.53

0.70

0.86

1.19

230V

50Hz

Export

0.58

0.76

0.96

1.34

120V

60Hz

Energy Efficient

0.50

0.58

0.80

1.10

230V

60Hz

Energy Efficient

0.35

0.40

0.50

0.65

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

Standard Lighting (T-8 fluorescent)

1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Optional Lighting (T-8 fluorescent)

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Additional 2 Row Canopy

0.51

1.02

1.02

1.54

59

118

118

170

Additional 3 Row Canopy

0.77

1.53

1.53

2.31

89

177

177

255

1 Row Rail Light

NA — Glass front does not accept rail light

Optional Shelf Lighting (T-8 fluorescent)

2 Rows of Shelves

0.51

1.02

1.02

1.54

59

118

118

170

3 Row Shelf Receptacle

1.53

2.31

177

255

Optional Always*Bright LED Lighting

2 Rows of Shelves

0.26

0.34

0.47

0.67

31

41

56

80

120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52

Summary of Contents for Impact Excel M3X-GE

Page 1: ...Fan Assembly 1 0058698 Fan Motor Evaporator MO 4410102 0142780 Fan Blade FB 0142780 7W Energy Efficient Fan Assembly 1 0477654 Fan Motor Evaporator MO 4410545 0142780 Fan Blade FB 0142780 Item Part De...

Page 2: ...external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 70 2 3 4 70 2...

Page 3: ...Temperature Pressure Chart to deter mine PSIG conversions Estimated Charge lb M3X GE 4 ft 1 4 6 ft 1 9 8 ft 2 7 12 ft 3 9 This is an average for all refrigerant types Actual refrigerant charge may va...

Page 4: ...1 19 230V 50Hz Export 0 58 0 76 0 96 1 34 120V 60Hz Energy Efficient 0 50 0 58 0 80 1 10 230V 60Hz Energy Efficient 0 35 0 40 0 50 0 65 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Cu...

Page 5: ...56 m3 m ARI Total Display Area 3 Sq Ft Ft 3 49 ft2 ft 1 06 m2 m Shelf Area 4 Sq Ft Ft 5 35 ft2 ft 1 63 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft...

Page 6: ...ow Canopy 3 Row Canopy B 4 ft 6 ft or 8 ft 12 ft R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchand...

Page 7: ...FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for...

Page 8: ...7 7 R BL R BL R BL 7 7 R BL R BL BL BL TYP Shelf Light Plug Receptacle R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground an...