4 ft
6 ft
8 ft
12 ft
General
(A)
Case Length
(without ends or partitions)
48
3
/
8
(1229)
72
3
/
8
(1838)
96
3
/
8
(2448)
144
1
/
2
(3670)
(Each end and insulated partition adds 1
1
/
2
in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper)
42 (1064)
42 (1064)
42 (1064)
42 (1064)
Back of case to front of splashguard
38
3
/
8
(975)
38
3
/
8
(975)
38
3
/
8
(975)
38
3
/
8
(975)
Back of case to O/S edge of front rails
30
1
/
4
(767)
30
1
/
4
(767)
30
1
/
4
(767)
30
1
/
4
(767)
Distance between edges of external rails and center rails
NA
29
1
/
2
(750)
41
1
/
2
(1054)
41
1
/
2
(1054)
Distance between edges of center rails
NA
NA
NA
43
7
/
8
(1114)
Distance between front rails and splashguard
8 (203)
8 (203)
8 (203)
8 (203)
Electrical Service
(Electrical Field Wiring connection point located on top of case)
(B)
RH End of case to center of 4 x 4 x 2 Electrical Box
39
3
/
8
(1000)
63
3
/
8
(1610)
87
3
/
8
(2219)
135
1
/
2
(3442)
Back of case to center of 4 x 4 x 2 Electrical Box
17
3
/
4
(451)
17
3
/
4
(451)
17
3
/
4
(451)
17
3
/
4
(451)
Waste Outlets
(One each end)
(C)
RH End of case to the center of LH waste outlet
36
1
/
4
(921)
60
1
/
4
(1530)
84
1
/
4
(2140)
132
3
/
8
(3363)
RH End of case to the center of RH waste outlet
12
1
/
8
(307)
12
1
/
8
(307)
12
1
/
8
(307)
12
1
/
8
(307)
Back O/S of case to center of waste outlets
36
3
/
4
(933)
36
3
/
4
(933)
36
3
/
4
(933)
36
3
/
4
(933)
Schedule 40 PVC drip pipe
1
1
/
4
(32)
1
1
/
4
(32)
1
1
/
4
(32)
1
1
/
4
(32)
Refrigeration Outlet
Back of case to center of refrigeration outlet
26
1
/
4
(665)
26
1
/
4
(665)
26
1
/
4
(665)
26
1
/
4
(665)
RH end of case to center of refrigeration outlet
8 (203)
8 (203)
8 (203)
8 (203)
2 of 8
D6X-ULEP
Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Ultra Low Front
Dairy & Delicatessen
03-2007
4
3
/
4
(120)
Splashguard
36
3
/
4
(933)
42
(1064)
A
41
1
/
2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical Box
Waste Outlet
Waste Outlet
FRONT
26
1
/
4
(665)
C
B
8
(203)
4
1
/
2
(115)
12
1
/
8
(307)
41
1
/
2
(1054)
43
7
/
8
(1114)
4
3
/
4
(120)
4
1
/
4
(108)
17
3
/
4
(451)
38
3
/
8
(975)
30
1
/
4
(767)
9
(229)
D6X
Note: ALL FIELD WIRING CONNECTION POINTS ARE ABOVE THE CASE.
Case to case connections are made in the electrical box at the top of
the case.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
1
/
4
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
7
/
8