background image

ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

600 (272)

800 (363)

1000 (454)

1200 (544)

75 (34)

5

Actual weights will vary according to optional kits included.

5 of 10

P/N 0466005_H

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Impact  

Excel

C2X-XLEP

Dairy/Delicatessen

Precut & Packaged Produce

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

3.72 ft

3

/ft  (0.35 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

3.62 ft

/ft  (0.34 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

3.50 ft

2

/ft  (1.07 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

6.38 ft

2

/ft  (1.94 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product Reference Guide

. The standard shelf complement for this model is (1) row of 12-inch shelf, 

(1) row of 16-inch shelf and (1) row of 18-in shelf.

eparately from fans.

Summary of Contents for impact Excel C2X-XLEP

Page 1: ...Fan Motor Evaporator MO 4410101 0382383 Fan Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 THERMOSTATS B Optional Adjustable...

Page 2: ...een edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 7...

Page 3: ...ST DATA C2X XLEP Frequency hr 8 Defrost Water lb ft day 7 15 based on case configuration and product loading OFFTIME C2X XLEP Time minutes 30 ELECTRIC OR GAS Not Recommended CONVENTIONAL CONTROLS Low...

Page 4: ...ficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V 50 60Hz Standard 0 10 0 15 0 20 0 30 12 18 24 36 S...

Page 5: ...Total Display Area 3 Sq Ft Ft 3 50 ft2 ft 1 07 m2 m Shelf Area 4 Sq Ft Ft 6 38 ft2 ft 1 94 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m 2 ARI Ref...

Page 6: ...r BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 5 4 5 5 Connector W B BL BL R BL R R R Optional Lighting 1 Row Rail B 4 f...

Page 7: ...echanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4 ft case 5 5 5 B W 6 ft...

Page 8: ...L R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 7 7 7 7 7 7 7 R BL 6 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Page 9: ...shelves The depth of the shelf used in the top eight 8 shelf hole locations is critical to case performance If a shelf is placed in one of the top eight 8 locations it must comply with the angle depth...

Page 10: ...ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of...