REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75 (

°

F)

and 55% R.H.

E3

Discharge Air (°F)

29

Evaporator

(

°F)

21

Unit Sizing 

(

°F)

19

Btu/hr/ft*

E3

Parallel

1180

Conventional

1280

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

E3

Frequency (hr)

6

Defrost Water 

8 lb/ft/day

(± 15% 

based on case configuration and

product loading).

O

FFTIME

E3

Temp Term 

(

°F)

48

Failsafe (minutes)

40

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise: close  48°F – open  33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control
CI/CO

**

E3

Temp  

(

°F)

14 / 4

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)

**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

E3

4 ft

0.9

6 ft

1.8

8 ft

1.9

12 ft

2.9

***This is an average for all refrigerant types
actual refrigerant charge may vary by 
approximately half a pound.

Length (in.) Added to Lineup by Each
End or Insulated Partition

1

3 of 7

P/N 0453527A

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

15 

3

/

4

(400)

25 

3

/

8

(645)

55 

7

/

8

(1419)

12

(305)

22

(559)

34 

1

/

2

(876)

46 

1

/

2

(1181)

12

(305)

27 

5

/

8

(702)

30 

3

/

4

(781)

31 

(787)

FAN

C

O

I

L

35 

1

/

4

(895)

E3

1

/

4

(108)

 Refrigeration
 Outlet

Impact 

Elite

E3

Delicatessen

Precut & Packaged Produce

Elite Specialty Merchandiser Multi-deck,  3  Display Levels

Dimensions shown as in. & (mm).

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF

®

) Standard #7 requirements. 

See Page 7 for
shelf arrangement.

Summary of Contents for IMPACT Elite E3

Page 1: ...ription Wiring Item LAMPS AND BALLASTS D 0466234 Ballast Electronic 2 lamps 4 D 0466235 Ballast Electronic 3 lamps 4 D 0466236 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures HUSSMANN CORPORATION Bridgeton MO 63044 2483 U S A Note Changed items have been underlined E3 Data Sheet Set P N 0453527A NSF Certified October 2005 We reserve the right to change or revise specif...

Page 2: ... 8 752 29 5 8 752 29 5 8 752 29 5 8 752 D RH End of case to RH end of raceway 27 5 8 702 51 5 8 1311 57 1 4 1454 105 1 8 2670 E LH End of case to LH end of raceway 2 1 8 54 2 1 8 54 2 51 2 1 4 57 Waste Outlet F RH End of case to the center of waste outlet 24 1 4 616 24 1 4 616 24 1 2 622 72 1 4 1834 LH End of case to the center of waste outlet 23 7 8 606 47 7 8 1216 71 3 4 1822 72 1 8 1832 Back O ...

Page 3: ...ture Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E3 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length in Added to Lineup by Each End or Insulated Partition 1 3 of 7 P N 0453527A HUSSMANN CORPORATION Brid...

Page 4: ...Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 70 1 20 1 20 1 70 With Energy Efficient Fans 120V 60 Hz 0 46 0 72 0 72 0 98 With Export Fans 230V 50Hz 0 48 0 76 0 76 1 04 Maximum Over Current Protection 20 20 20 20 Export 230V 50Hz 15 15 15 15 Electric Defrost Heaters 208V 1Ph NA Standard Lighting 2 Rows Canopy 0 51 1 01 1 01 1 52 66 122 122 183 Optional Light...

Page 5: ...s must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shel...

Page 6: ...nents in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R 5 R R 6 of 7 E3 Data Sheet HUSSMANN CORPORATION Bridgeton M...

Page 7: ...e locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal case performance Check with Hussmann engineering before using a different configuration Impact Elite E3 Delicatessen Precut Packaged Produce 7 of 7 P N 0453527A HUSSMANN CORPORATION Bridgeton MO 6304...