REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75 (

°

F) and 55% R.H.

E2SPH

Meat

Deli

Discharge Air (°F)

25

28

Evaporator

(

°F)

18

21

Unit Sizing 

(

°F)

16

19

Btu/hr/ft* 

E2SPH

Parallel

900

890

Conventional

1000

980

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

E2SPH

Frequency (hr)

6

Defrost Water 

8 lb/ft/day

(± 15% 

based on case configuration and product

loading).

O

FFTIME

E2SPH

Temp Term 

(

°F)

48

Failsafe (minutes)

40

E

LECTRIC OR

G

AS

Not Recommended

Standard Defrost Thermostat

Close on rise: close  48°F – open  33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control  CI/CO

**

E2SPH

Meat

Deli

Temp (°F)

11 / 6

14 / 4

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)

**

48°F

**Use a Temperature Pressure Chart to determine
PSIG conversions.

PHYSICAL DATA

Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)*** E2SPH

4 ft

0.9

6 ft

1.8

8 ft

1.9

12 ft

2.9

***This is an average for all refrigerant types actual
refrigerant charge may vary by approximately half a
pound.

Length Added to Lineup by Each 
End or Insulated Partition

1 in.

3 of 8

P/N 0453532

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

C
O

I

L

Refrigeration
Outlet

FAN

Hot

Wells

(2)

Control

Box

Electrical
Connection

12

(305)

22

(559)

40 

1

/

4

(1022)

35

(889)

3

/

4  

(248)

12

(305)

19 

1

/

8

(486)

31

(787)

E2SPH

31 

1

/

4

(794)

28 

1

/

8

(714)

20

(508)

Standard Curved
Sneeze Guard

53 

3

/

4

(1365)

47

(1194)

63

(1600)

3

/

(121)

1

/

4

(235)

36

(914)

16

(406)

5

/

8

(219)

Impact 

Elite

E2SPH

Meat, Delicatessen

Precut & Packaged Produce

Elite Specialty Merchandiser Multi-deck, 2 Display Levels, Prep Top, Hot
Wells

Dimensions shown as in. & (mm).

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF

®

) Standard #7 requirements. 

See Page 8 for
shelf arrangement.

Summary of Contents for IMPACT Elite E2SPH

Page 1: ...embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0353949 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0466234 Ba...

Page 2: ...center of waste outlet 24 1 4 616 LH End of case to the center of waste outlet 23 7 8 606 Back O S of case to center of waste outlet 28 1 8 714 Water Seal Edge of water seal to center of waste outlet...

Page 3: ...ns PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb E2SPH 4 ft 0 9 6 ft 1 8 8 ft 1 9 12 ft 2 9 This is an average for all refrigerant types actual refrigeran...

Page 4: ...ndard 0 90 120V 50Hz Standard 1 01 230V 60Hz Export 0 53 230V 50Hz Export 0 58 120V 60Hz Energy Efficient 0 58 230V 60Hz Energy Efficient 0 39 Maximum Over Current Protection 120V 20 Maximum Over Curr...

Page 5: ...0 V Power B W G B BL G W BL Shelf Harness Shelf Light Circuits 4 W R G R Shelf Lighting G R 5 Connector Connector B 4 ft case has 1 Fan 4 ft BL Connector G 120V POWER 120V NEUTRAL Field GROUND Case GR...

Page 6: ...TRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND BL R 4 5 R 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B 4 ft case has 1 Lamp BL R 4 5 R 4 ft case...

Page 7: ...at LH or RH Well Marker R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL Field GROUND Case GROUND WARNING All components must have mechanical ground and the merchandiser must be...

Page 8: ...e two locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides opt...

Reviews: