background image

4 of 6

CW2GE 

Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

CW2-GE

Convertible Island

Electrical Data

Number of Fans 

4 ft

8 ft

12 ft

Refrigeration – 6W

2

4

6

Amperes

Watts

Merchandiser

4 ft

8 ft

12 ft

4 ft

8 ft

12 ft

Fans (Refrigeration)

Standard (120V 60Hz)

1.00

2.00

3.00

78

156

234

Energy Efficient (120V 60Hz)

0.52

1.04

1.56

36

72

108

Cycling Anti-sweat Heaters

NA

NA

NA

NA

NA

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz) 

1.20

2.20

3.20

With Energy Efficient Fans (120V 60Hz)

0.74

1.24

1.76

Maximum Over Current Protection 120V

20

20

20

Electric Defrost Heaters (208V 1

Φ

Φ

)

NA

NA

NA

NA

NA

NA

Standard Lighting

4 ft

8 ft

12 ft

4 ft

8 ft

12 ft

1 Row Canopy

0.51

1.02

1.54

59

118

177

Optional Lighting

2 Rows Canopy 

1.02

2.04

3.08

118

236

354

Optional Shelf Lighting

1 Row of Shelves

0.51

1.02

1.54

59

118

177

2 Rows of Shelves

1.02

2.04

3.06

118

236

354

Summary of Contents for IMPACT CW2-GE

Page 1: ...698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0398558 Standard Non adjustable 2 Defrost Thermostat C 0144732 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures CW2 GE Data Sheet Set P N 0399334B NSF Cert...

Page 2: ...2 1 8 54 2 1 8 54 2 1 8 54 Stub up area between front base rail and splashguard 7 1 4 184 7 1 4 184 7 1 4 184 Electrical Service Note Electrical Field Wiring connection point Center of Electrical service to O S edge of front base rail 7 178 7 178 7 178 Right end of case to center of knockout 5 127 5 127 5 127 Length of electrical raceway 46 5 8 1184 46 5 8 1184 46 5 8 1184 Waste Outlet B LH End of...

Page 3: ...llel 1480 Conventional 1640 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA CW2GE Frequency hr 6 Defrost Water lb ft day 10 15 based on case configuration and product loading OFFTIME CW2GE Temp Term F 48 F Failsafe minutes 45 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure ...

Page 4: ...1 56 36 72 108 Cycling Anti sweat Heaters NA NA NA NA NA NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 1 20 2 20 3 20 With Energy Efficient Fans 120V 60Hz 0 74 1 24 1 76 Maximum Over Current Protection 120V 20 20 20 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA NA NA Standard Lighting 4 ft 8 ft 12 ft 4 ft 8 ft 12 ft 1 Row Canopy 0 51 1 02 1 54 59 118 177 Optional Lighting 2 Rows Canopy...

Page 5: ... Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B Refrigeration Thermostat To Condensing Unit Field Installed 3 4 Dark Blue Defrost Termination Thermostat BROWN BAND Fans BROWN BAND 120V POWE...

Page 6: ...120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS...