REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H.

CW2EXGE

Discharge Air (°F)

28

Evaporator (°F)

21

Unit Sizing (°F)

19

Btu/hr/case*

CW2EXGE

Parallel

4800

Conventional

5300

\

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

CW2EXGE

Frequency (hr)

6

Defrost Water (lb/ft/day)

8

(± 15% 

based on case configuration and

product loading).

O

FFTIME

CW2EXGE

Temp Term (°F)

48

°

Failsafe (minutes)

45

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat

Close on rise: close 48°F — open 33°F

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CW2EXGE

CI/CO (Temp °F)

**

17°/ 7°

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)**

48°

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser
Drip Pipe (in.)

1

/

4

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)*** CW2EXGE 

1.7

***This is an average for all refrigerant
types. Actual refrigerant charge may vary by 
approximately half a pound.

Length Added to Lineup by:
Each End/Partition (in.)

1

/

2

3 of 6

P/N 0406610B

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

I

18 in. Shelf

16 in. Shelf

12 in. Shelf

10 

3

/

4

(273)

30 

1

/

8

 

(765)

32

(813)

3

/

8

 

(162)

FAN

COIL

54

(1372)

(178)

7

/

8

 

(98)

1

/

2

 

(216)

28 

3

/

8

(721)

40 

3

/

4

(1035)

Front

of

Case

5

(127)

26

(660)

(127)

21

(533)

(229)

Dimensions shown as inches and (mm).

Wide Island End, 1 Display Level

NSF Certification

These merchandisers are manufactured to meet ANSI /National 
Sanitation Foundation (NSF ®) Standard #7 requirements. 

Impact  

CW2EGE

Convertible Island End

CW2EGE

Reviews: