background image

6 of 8

C2-XGEP 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Standard Lighting  1 Row Canopy  or Optional 1 Row Rail

Light Circuits

Optional  Lighting  2 Rows Canopy

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light 

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

 

B

AND

B

B

W

BL

R

R

BL

BL

4

BL

R

R

BL

BL

4

5

5

5

120V N

EUTRAL

O

RANGE

 

OR

 T

AN

 B

AND

W

Light 

Switch

120V P

OWER

O

RANGE

 

OR

 T

AN

 

B

AND

B

BL

R

R

BL

BL

4

5

5

R

R

5

Grayed components in 12 foot models only. 

 

R = Red   Y = Yellow  G = Green  BL = Blue   B = Black   W = White

=  120V P

OWER

=  120V N

EUTRAL

WARNING 

All components must have mechanical ground, and the merchandiser must be grounded.

C

IRCLED

 

NUMBERS

 = P

ARTS

 L

IST

 I

TEM

 N

UMBERS

R

5

5

5

Note: Optional Construction for 2 Rows Canopy on the 8 ft would be to wire (1) 4-lamp ballast.

Summary of Contents for Impact C2-XGEP

Page 1: ...ES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0137880 Optional Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item...

Page 2: ...2 140 5 1 2 140 Distance between edges of external and center supports NA 31 1 8 790 40 5 8 1032 40 5 8 1032 Distance between edges of center supports 41 1 4 1048 NA NA 44 1118 Stub up area between fr...

Page 3: ...conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average f...

Page 4: ...70 120V 50Hz Standard 0 75 2 05 2 05 2 85 230V 60Hz Export 0 45 1 45 1 45 1 95 230V 50Hz Export 0 48 1 51 1 51 2 04 120V 60Hz Energy Efficient 0 46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum...

Page 5: ...RS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connector Connector Connect...

Page 6: ...R BL BL 4 BL R R BL BL 4 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green...

Page 7: ...placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 12 in 15 14 in or less 30 18 in or less 45 18 in or less NOT...

Page 8: ...hen facing case of the merchandiser To access the ballast 1 Remove screws from the front lip of light tray flange covering the bottom edge of the canopy Also remove screws located near the middle rear...

Reviews: