IGHT-HEDN, HEDN COMBO, HEDW-0508
4
Installation
IMPORTaNT! IT Is IMPERaTIvE THaT CasEs BE
LEvELED FROM FRONT TO BaCK aND sIDE TO sIDE
PRIOR TO JOINING. a LEvEL CasE Is NECEssaRY
TO INsURE PROPER OPERaTION, WaTER DRaINaGE,
GLass aLIGNMENT, aND OPERaTION OF THE HINGEs
sUPPORTING THE GLass. LEvELING THE CasE
CORRECTLY WILL sOLvE MOsT HINGE OPERaTION
PROBLEMs.
aLL CasEs WERE LEvELED aND JOINED
PRIOR TO sHIPMENT, TO INsURE THE CLOsEsT
POssIBLE FIT WHEN CasEs aRE JOINED IN THE
FIELD.
TO AVOID REMOVING CONCRETE FLOORING, BEGIN
LINEUP LEVELING FROM THE HIGHEST POINT OF
THE STORE FLOOR.
Leveling/Joining Instructions
Check floor where cases are to be set to see if it’s level.
Determine where the highest part of the floor is. Cases will
be shimmed off this point. Using case blueprints, measure
off and mark on floor the exact dimensions of the case
footprint. Snap chalk line for front and back position of
base rail. Mark location of each joint front and back. Use
a transit to find the highest point along both lines. Mark
the difference, and place the appropriate number of shims
required to maintain high - point level.
Electrical
Wiring Color Code
CASE MUST BE GROUNDED
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Heaters and Lights.
Electrical Circuit Identification
Standard lighting for all models will be full length fluorescent
lamps located within the case at the top. The switch
controlling the lights, the plug provided for digital scale,
and the thermometer are located at the rear of the case
mullion.
The receptacle that is provided on the exterior back of these
models is intended for computerized scales with a five amp
maximum load, not for large motors or other high wattage
appliances. It should be wired to a dedicated circuit.
Electrical service Receptacles
(When applicable)
The receptacles located on the exterior of the merchandiser
are intended for scales and lighted displays. They are not
intended nor suitable for large motors or other external
appliances.
Field Wiring and serial Plate amperage
Field Wiring must be sized for component amperes printed
on the serial plate. Actual ampere draw may be less than
specified. Most component amperes are listed in the “Wiring
Diagram” section, but always check the serial plate.
Ballast Location
Ballasts are located within the access panel that runs the
length of the rear of the case. Refer to diagram.