P/N 3003960_A
2-5
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
GSVM 4060F Merchandisers
1.
Apply power to the merchandiser. Wait for
the self check to complete. During the self
check, each LED flashes for one second and
then all LEDs turn on for two seconds. If the
LEDs do not flash, make sure the adjustment
knob is not in the “OFF” position.
1A.
The merchandiser temperature displays at
startup. The initial defrost starts two hours
later. The display will show the temperature at
the start of defrost. This reading will remain
displayed during defrost and until it times out,
even though the refrigeration mode has been
initiated. (The green LED will be lit.)
2.
The compressor will start after a 30 second
delay once power is applied.
3.
The compressor will continue to run until it
reaches its cut-out temperature (Pulldown).
4.
The refrigeration cycle will continue for the next
subsequent scheduled (24-hours) or demand
defrost. The digital display will display the
temperature reading for 10 minutes after
defrost.
5.
The above process will repeat (steps 3 and 4)
until the power is interrupted.
6.
If power stops, the process will start over at step
1, and the time to subsequent defrost will reset.
1 per day
GSVM 4060F
1 per day
45° F
Time 60 minutes
(Failsafe)
Time 60 Minutes
(Failsafe)
Summary of Contents for GSVM4060F