background image

EXTERIOR LOADING

Do NOT walk on top of merchandisers

 or  

damage to the merchandisers and serious  
personal injury could occur. 

merchandisers

 

are

 

not

 

structurally

 

designed

 

to

 

support

 

external

 

loading

 

such as the weight of a person. Do not place 
heavy objects on the merchandiser.

SHIPPING SKID

Each merchandiser is shipped on a skid to  
protect the merchandiser’s base, and to make  
positioning the case easier.

Do not remove the shipping skid until the  
merchandiser is near its final location.

 

The 

skid provides protection for both the merchan-
diser and the floor.

Remove the skid by raising one end of the  
merchandiser approximately 6 inches. Block the 
merchandiser securely, and remove the two skid 
bolts from the raised end. Replace the bolts 
with (provided) leg levelers. Repeat this proce-
dure at opposing end. Once the leg levelers are 
secured in place, the merchandiser may be slid 
off the skid and placed in its final location.

DO NOT TILT MERCHANDISER ON ITS 
SIDE OR END WHEN REMOVING SKID.

Once the skid is removed, the merchandiser 
must be lifted —NOT PUSHED— to reposition. 

Check floor where merchandisers are to be set 
to see if it is a level area. Determine the highest 
part of the floor.

MERCHANDISER LEVELING

B

e

 

sure

 

to

 

position

 

merchandisers

 

proper

-

ly

Level the merchandiser by all four corners. 

Merchandiser(s) must be installed level to 
ensure proper operation of the refrigeration 
system, and to ensure proper drainage of 
defrost water. 

OPTIONAL LEGS

NSF

® 

approved legs replace the leg levelers if 

required by local health codes. The legs raise 
the case 6 inches for cleaning purposes. An 
optional skirt kit can be provided to snap on 
the legs. 

P/N 0545719_B

 

1-3

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483  U.S.A.

GSVM Open Vertical Merchandisers

This product may contain chemicals known 

to the State of California to cause cancer, 

birth defects, or other reproductive harm.

This warning is the result of the California State 
law known as the California Safe Drinking Water 
and Toxic Enforcement Act of 1986, which is 
commonly referred to as “Proposition 65.”

This warning does not mean that Hussmann 
products will cause cancer or reproductive 
harm, or is in violation of any product-safety 
standards or requirements. As clarified by the 
California State government, Proposition 65 
can be considered more of a ‘right to know’ law 
than a pure product safety law. When used as 
designed, Hussmann believes that our products 
are not harmful. We provide the Proposition 65 
warning to stay in compliance with California 
State law. It is your responsibility to provide 
accurate Proposition 65 warning labels to your 
customers when necessary. For more information 
on Proposition 65, please visit the California 
State government website.

For California Businesses:

Summary of Contents for GSVM 4060D

Page 1: ...VM 4060D Medium Temperature Self Contained Vertical Merchandiser with Doors P N 0545719_B February 2015 Installation Operation Manual IMPORTANT Keep in store for future reference MANUAL IO SC GSVM 406...

Page 2: ......

Page 3: ...ORTANT KEEP IN STORE FOR FUTURE REFERENCE Quality that sets industry standards 12999 St Charles Rock Road Bridgeton MO 63044 2483 U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com 2015...

Page 4: ......

Page 5: ...perature Adjustment 2 7 Typical Sensor to Control Config 2 8 START UP OPERATION Start Up 3 1 Controls and Adjustments 3 1 Load Limits 3 1 Stocking 3 1 Shelf Weight Limits 3 2 MAINTENANCE Care and Clea...

Page 6: ...ptacle Page 2 1 Replaced Wiring Diagram GSVM 4060D 0528357 ORIGINAL ISSUE NOVEMBER 2012 vi ANSI Z535 5 DEFINITIONS DANGER Indicate s a hazardous situation which if not avoided will result in death or...

Page 7: ...r shipping damage before and during unloading This equipment has been carefully inspected at our factory Any claim for loss or damage must be made to the carrier The carrier will provide any necessary...

Page 8: ...NG Unloading from Trailer Lever Bar also known as a Mule Johnson Bar J bar Lever Dolly or Pry Lever Move the merchandiser as close as possible to its permanent location and remove all packaging Check...

Page 9: ...iser by all four corners Merchandiser s must be installed level to ensure proper operation of the refrigeration system and to ensure proper drainage of defrost water OPTIONAL LEGS NSF approved legs re...

Page 10: ...the other Sealing of the lower front and rear panels on self contained mod els may hamper their removal for servicing or maintenance of the condensing unit NOTE Do not allow trim to cover any intake...

Page 11: ...an extension cord 6 Ensure that the proper electrical requirements for the equipment are supplied 7 Verify field electrical connections are tight 8 Verify all electrical wiring is secured and clear o...

Page 12: ...1 6 Installation NOTES P N 0545719_B U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com...

Page 13: ...be dedicated for the merchandiser Failure to do so voids the warranty Do not use an extension cord Never plug in more than one merchandiser per electrical circuit Always use a dedicated circuit with...

Page 14: ...ms use a capillary tube for refrigerant control The capillary tube is soldered to the suction line pull out coil for proper heat exchange If the capillary should become plugged or damaged it is best t...

Page 15: ...ntrol for your chilled or frozen food The front of the controller has an adjustment knob and status LEDs The back of the controller has connections for sensors and switched equipment The Safe NET III...

Page 16: ...red up or is turned off and then back on a 2 digit Parameter Code Number will display for 3 seconds Then the Self Check will Start 2 Wait for the self check to complete During the self check each LED...

Page 17: ...even though the refrigeration mode has been initiated The green LED will be lit 2 The compressor will start after a 1 minute delay once power is applied 3 The compressor will continue to run until it...

Page 18: ...itch to a duty cycle operation During duty cycle operation the refrigeration system will cycle on and off until the sensor is serviced The graph below shows an example of duty cyle operation during a...

Page 19: ...shows the setpoint cut out value A few seconds after the temperature is set the controller reverts to the sensed temperature in the merchandiser 3 To verify merchandiser settings turn the dial to war...

Page 20: ...2 8 Installation P N 0545719_B U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com...

Page 21: ...ir temperature shown Measure discharge air temperatures at the center of the discharge honeycomb Defrosts are time initiated and time terminated for self contained The defrost setting is factory set a...

Page 22: ...LF MAXIMUM WEIGHT LIMITS Hussmann merchandiser shelves are designed to support the maximum weight load limits as indicated in the table below Exceeding these maximum weight load limits may cause damag...

Page 23: ...on any interior surfaces Do not use high pressure water hoses Do Disconnect electrical power before cleaning Remove the product and all loose debris to avoid clogging the waste outlet Store product i...

Page 24: ...of the stainless steel finish Do not use bleach CLEANING SOLAR THERMOMETER GSVM models have solar thermometers The thermometer is located at the top front center of the merchandiser s cabinet interio...

Page 25: ...er failure The evaporation pan waste water will overflow and spill onto the floor if the heater is not properly operating Remove accumulated debris from the evapora tion pan Wipe down heater coil with...

Page 26: ...ow blockage increases energy consump tion and reduces the merchandiser s ability to maintain operating temperature To clean the coils use a vacuum cleaner with a wand attachment and a soft non metalli...

Page 27: ...the unit Heat and air registers fans and doors etc x Check for water leaks x Clean evaporator coil s and fan blade s Do not use an acid base cleaner Rinse off any cleaner residue x Clean discharge ai...

Page 28: ...4 6 Maintenance NOTES P N 0545719_B U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com...

Page 29: ...the correct direction 10 Reinstall display pans Bring merchandiser to operating temperature before restocking CLEANING COILS NEVER USE SHARP OBJECTS AROUND COILS Use a soft brush or vacuum brush to c...

Page 30: ...rformed by two technicians 5 Rotate the LED fixture to release it from the lamp holder 6 Change LED light and replace with like fixture REPLACING SOLAR THERMOMETER GSVM models have solar thermometers...

Page 31: ...too warm 4 Refrigerant over charge 5 Low voltage compressor cycling on overload 1 Short of refrigerant 2 Inefficient compressor 3 Coil iced up 1 Defective control 2 Control sensing element not in pos...

Page 32: ...ble for the GSVM Caster Kit Consists of 5 in braking casters which screw in to the standard threaded holes in the four corners under the cage occupied by the standard leg levelers The kit will add 5 5...

Page 33: ...dered to be used with the wire partition kit above Wire Basket Kits One kit is available to replace the top 13 in shelf or shelves another is available to replace the bottom 15 in shelf Each kit consi...

Page 34: ...NOTES P N 0545719_B U S Canada 1 800 922 1919 Mexico 1 800 890 2900 www hussmann com 5 6 Service...

Page 35: ...afe Net III Display F 65C H159052 Safe Net III Display Interface Cable 0509783 Safe Net III Control Harness 0513058 Compressor Relay T92P7A22 120 0459304 Condensate Pan Heater Relay SPDT NC 120V 03425...

Page 36: ...ket 0527860 Side Plexiglass End LH RH 0526342 Side Bracket Door LH Sliver 0537797 Side Bracket Door RH Sliver 0537798 Door Closer Kit 2 0527355 Condensing Unit Assy 0528494 Compressor NEK6187Z 1 3hp 2...

Page 37: ...andiser with Doors Appendix A Technical Data A 3 GSVM 4060D General GSVM 4060D Case Length Note Includes One Pair Ends 40 in 1016 mm Optional End Bumpers One Pair 2 in 51 mm Waste Outlet LH end of cas...

Page 38: ...at std rating conditions DEFROST DATA Frequency hour GSVM 4060D 6 Offtime Failsafe minutes GSVM 4060D 45 Defrost Termination Temperature Terminated PHYSICAL DATA Refrigerant Charge GSVM 4060D R134a 1...

Page 39: ...total merchandiser electrical load GSVM 4060D Number of Fans 4W open shell 2 Amperes Watts Evaporator Fans 115V 60Hz 0 12 4 Condensate Pan Heaters 115V 3 350 GSVM 4060D Condensing Unit 115V 1Ph 60Hz S...

Page 40: ...co 1 800 890 2900 www hussmann com A 6 Appendix A Wiring Diagrams ESTIMATED SHIPPING WEIGHT 2 Self Contained Case with Shipping Crate End GSVM 4060D 520 lb 236kg Included 2 Actual weights will vary ac...

Page 41: ...BK W RELAY W LEVEL SWITCH NEMA 5 15P BK W LINE 1 LINE 2 COMP NA PHASE FAN PHASE THERMOSTAT SENSOR AIR TEMP THERMOSTAT SENSOR TEMP DEFROST HEATER SAFENET III CONTROL BK BK W BL BK W Y B 1 2 3 4 5 6 7 8...

Page 42: ...information or other support contact your Hussmann representative Please include the model and serial number of the product Hussmann Corporation Corporate Headquarters Bridgeton Missouri U S A 63044 2...