Impact  

Excel

FWG

Low / Medium Temperature 

ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

1000 (454)

1200 (544)

1400 (635)

1600 (726)

75 (34)

5

Actual weights will vary according to optional kits included.

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

3.50 ft

3

/ft  (0.33 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

7.30 ft

/ft  (0.68 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

2.75 ft

2

/ft  (0.84 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

5.52 ft

2

/ft  (1.68 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product Reference Guide

. The standard shelf complement for this model is 

NONE

.

Summary of Contents for FWG

Page 1: ...41 0465906 6 ft case HE 4850628 0465907 8 ft case HE 4850622 0465908 12 ft case HE 4850623 H Nosing Anti sweat Heaters 8 0495009 4 ft case HE 4850687 0495006 6 ft case HE 4850684 0495007 8 ft case HE...

Page 2: ...between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 12 3 8 312 12 3 8 312 12 3 8 312 12 3 8 312 Electrical Service Electrical Field Wiring connection point B...

Page 3: ...e Defrost Termination Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb 4 ft 1 7 6 ft 2 1 8 ft 2 5 12 ft 3 7 This is an average for all refrigerant typ...

Page 4: ...0Hz Standard 0 87 1 30 1 74 2 60 104 156 208 312 230V 50 60Hz Export 0 45 0 68 0 90 1 36 104 156 208 312 Minimum Circuit Ampacity 120V 60Hz Standard 1 69 2 12 3 18 4 04 120V 50Hz Standard 1 83 2 26 3...

Page 5: ...Ft Ft 7 30 ft3 ft 0 68 m3 m ARI Total Display Area 3 Sq Ft Ft 2 75 ft2 ft 0 84 m2 m Shelf Area 4 Sq Ft Ft 5 52 ft2 ft 1 68 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m...

Page 6: ...3 Light Blue 2 To Condensing Unit Refrigeration Thermostat Optional 1 BROWN BAND Fans BROWN BAND Nosing Anti sweat Heater 120V POWER 120V NEUTRAL 8 9 Return Grille Anti sweat Heater 1 BROWN BAND BROW...

Page 7: ...must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers Grayed components in 12 foot models only 7 4 120V Drip Pan Heater Koolgas Only Yellow Heater S...