rev. 0508 

3

Cut and Plan views

Fan

FMSS

Remote

Self-Service Shown with

Optional Special Height

Scale = 1"

*24"

*26"

*Dimensions

adjust at these

points to match

service case

height

13

1

/

2

"

12

1

/

4

"

6

1

/

8

"

*1

0

1

/

2

"

16"

FMSS

Front-Mount Self-Service case. Can be ordered to mount in front

of ANY service case. Base height can be modified to match any

service case bumper height.

ASC

PARENT CASE

FMSS

Height Modified to

 match the ASC case

20"

“Field” Close Off

4'

(VARIABLE LENGTHS)

3

1

/

2

"

4

1

/

2

"

12

1

/

2

"

24"

9

7

/

8

"

16

"

2

5

/

8

"

Ref. Drop In

Elec.

Drain

FMSS

Plan View

Scale = 1/2"

installation

location

The  refrigerated  merchandisers  have  been  designed 

for use only in air conditioned stores where temperature 

and humidity are maintained at or below 75°F and 55% 

relative humidity. DO NOT allow air conditioning, electric 

fans, ovens, open doors or windows (etc.) to create air 

currents around the merchandiser, as this will impair its 

correct operation.
Product  temperature  should  always  be  maintained  at  a 

constant and proper temperature. This means that from the 

time the product is received, through storage, preparation 

and  display,  the  temperature  of  the  product  must  be 

controlled to maximize life of the product.

Uncrating the stand

Place  the  fixture  as  close  to  its  permanent  position  as 

possible. Remove the top of the crate. Detach the walls 

from each other and remove from the skid. Unbolt the case 

from the skid. The fixture can now be lifted off the crate 

skid. 

lift only at base of stand!

exterior loading

These  models  have 

not

  been  structurally  designed  to 

support excessive external loading. 

do not walk on their 

tops;

 This could cause serious personal injury and damage 

to the fixture.

setting and Joining

The case that the FMSS connects to (the parent case) 

through the rear of the case must be leveled and set prior 

to installing the FMSS. The sectional construction of these 

models enable them to be joined in line - to give the effect of 

one continuous display. A joint Trim Kit is supplied with each 

case line to cosmetically “mask” the sectional joints.

leveling

iMPortant!  it  is  iMPerative  that  Cases  Be 

leveled froM front to BaCK and side to side 

Prior to Joining. a level Case is neCessarY 

to insUre ProPer oPeration, Water drainage, 

glass alignMent, and oPeration of the hinges 

sUPPorting  the  glass.  leveling  the  Case 

CorreCtlY Will solve Most hinge oPeration 

ProBleMs.

Summary of Contents for FMSS

Page 1: ...FMSS Case front Self Service Refrigerated Merchandiser P N IGSS FMSS 0508 INSTALLATION OPERATION GUIDE CHINO FMSS Case front Self Service Rev 0508 Installation Operation Manual...

Page 2: ...splay when positioned in front of a Parent service case Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully in...

Page 3: ...preparation and display the temperature of the product must be controlled to maximize life of the product Uncrating the Stand Place the fixture as close to its permanent position as possible Remove th...

Page 4: ...t case Apply heavy amount to cover entire shaded area DO NOT USE PERMAGUM Fig 2 1 It is the contractor s responsibility to install case s according to local construction and health codes 6 Slide secon...

Page 5: ...the machine room Refrigeration Lines Liquid Suction 3 8 O D 5 8 O D NOTE The standard coil is piped at 5 8 suction however the store tie in may vary depending on the number of coils and the draw the c...

Page 6: ...Measure the temperature of the suction gas at the thermostatic remote bulb location 4 Subtract the saturation temperature obtained in step No 2 from the temperature measured in step No 3 5 The differe...

Page 7: ...roduct but rather to maintain an item s proper temperature for maximum shelf life To achieve the protection required always 1 Minimize processing time to avoid damaging temperature rise to the product...

Page 8: ...ERANDAMILD DETERGENT FOR THE EXTERIOR ONLY DO NOT USEABRASIVES OR STEEL WOOL SCOURING PADS these will mar the finish Soap and hot water are not enough to kill this bacteria A sanitizing solution must...

Page 9: ...play pans Copper Coils The copper coils used in Hussmann merchandisers may be repaired in the field Materials are available from local refrigeration wholesalers Hussmann recommends using 15 Sil Fos fo...

Page 10: ...4406 1 2 3 1 1 06 22 04 H WIRESCHEMATICS NEW WIRING FMSS CASES W1400010 2 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE SWITCH TOGGLE 125 01 0307 L1...

Page 11: ...4406 1 2 3 1 1 07 29 02 H WIRESCHEMATICS NEW WIRING FMSS CASES W1400000 4 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BALLAST 125 01 0681 MAGNETEK...

Page 12: ...02 H WIRESCHEMATICS NEW WIRING FMSS CASES W1400001 6 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BALLAST 125 01 0681 MAGNETEK B260I120HP SWITCH TO...

Page 13: ...0014 6 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BALLAST 125 01 0681 MAGNETEK B260I120HP SWITCH TOGGLE 125 01 0307 L1 N 115 VAC 50 50 Hz L1 N 115...

Page 14: ...01 1802 1 2 3 4 5 6 TO 24VAC CLASS 2 50VA SOURCE GROUND NONE NONE AUX GROUND AUX GROUIND EINSTEIN CPC CC 100 CONTROLLER 225 01 3540A 7 8 9 10 11 12 NONE TO 24VAC CLASS 2 50 VA SOURCE FANS LIGHTS ANTI...

Page 15: ...406 1 2 3 1 1 07 29 02 H WIRESCHEMATICS NEW WIRING FMSS CASES W1400002 8 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BALLAST 125 01 0681 MAGNETEK B...

Page 16: ...9 02 H WIRESCHEMATICS NEW WIRING FMSS CASES W1400003 10 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BALLAST 125 01 0681 MAGNETEK B260I120HP SWITCH...

Page 17: ...SS CASES W1400011 11 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BALLAST 125 01 0681 MAGNETEK B260I120HP L1 N 115 VAC 50 60 Hz BUNDLE COLOR BROWN E...

Page 18: ...4910 LIC 644406 1 2 3 1 1 07 29 02 H WIRESCHEMATICS NEW WIRING FMSS CASES W1400004 12 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE BALLAST 125 01 06...

Page 19: ...1 0311 CIRCUIT 1 BALLAST 125 01 3266 FULHAM LH3 120 L LIGHT SWITCH TIPPETTE 125 01 0311 LIGHT SWITCH TIPPETTE 125 01 0311 BUNDLE ORANGE LABELED LIGHT CIRCUIT BUNDLE BROWN LABELED FAN CIRCUIT 120 VAC 6...

Page 20: ...1 CIRCUIT 1 BALLAST 125 01 3266 FULHAM LH3 120 L LIGHT SWITCH TIPPETTE 125 01 0311 LIGHT SWITCH TIPPETTE 125 01 0311 BUNDLE ORANGE LABELED LIGHT CIRCUIT BUNDLE BROWN LABELED FAN CIRCUIT 120 VAC 60 Hz...

Page 21: ...ID VALVE 225 01 3206 LIGHT SWITCH TOGGLE 125 01 0329 EVAPORATOR MOTORS EBM PAPST MODEL 3306 4 3 AXIAL 0 14A 12W 120V 00001212A CONDUCTIVE GLASS HEATER 60W 0 5A 120 VAC 2 150 01 7797 180W 1 5A 120VAC 2...

Page 22: ...aller should perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with...

Page 23: ...warm product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air flow and mix...

Page 24: ...erature recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising products to ensure that pot...

Page 25: ...________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________...

Reviews: