4 of 6
ESBDS
Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact Elite
ESBDS
Meat & Delicatessen
Electrical Data
Number of Fans
4 ft
6 ft
8 ft
12 ft
Refrigeration (
120V 60hz)
– 4W
1
2
2
3
Ambient Air Wipe – 15W
2
4
4
6
Export Refrigeration
(230V 50 hz )
– 4W
1
2
2
3
Export Ambient Air Wipe – 15W
2
4
4
6
Amperes
Watts
Merchandiser
4 ft
6 ft
8 ft
12 ft
4 ft
6 ft
8 ft
12 ft
Refrigeration Fans
Standard
(
120V 60hz)
0.31
0.62
0.62
0.93
24
48
48
72
Energy Efficient
(
120V 60hz)
0.14
0.28
0.28
.42
10
20
20
30
Export (230V 50 hz)
0.18
0.36
0.36
0.56
27
54
54
81
Ambient Air Wipe Fans
Standard
(
120V 60hz)
0.52
1.04
1.04
1.56
45
90
90
135
Export (230V 50 hz)
0.30
0.60
0.60
0.90
50
100
100
150
Constant-on Anti-Sweat Heaters (On/Off Switch Optional)
Standard
(
120V 60hz)
3.34
6.68
6.68
10.02
400
800
800
1200
Export (230V 50 hz)
1.74
3.48
3.48
5.22
400
800
800
1200
Minimum Circuit Ampacity
With Standard Fans
(
120V 60hz)
3.95
7.69
7.69
11.44
With Energy Efficient Fans
(
120V 60hz) 3.78
7.35
7.35
10.93
With Export Fans (230V 50 hz )
2.20
4.20
4.20
6.21
Maximum Over Circuit Protection 120V
20
Maximum Over Circuit Protection 230V
15
Standard Lighting* (
120V 60hz)
4 ft
6 ft
8 ft
12 ft
4 ft
6 ft
8 ft
12 ft
2 Row Canopy
0.49
0.98
0.98
1.42
59
118
118
171
Optional Lighting
1 Row Rail
0.49
0.49
0.49
0.71
59
59
59
86
1 Row Ledge
0.49
0.49
0.49
0.71
59
59
59
86
1 Row Shelves
0.49
0.49
0.49
0.71
59
59
59
86
2 Row Shelves
0.49
0.98
0.98
1.42
59
118
118
171
115V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting
230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52
do