REFRIGERATION DATA
Note:
This data is based on store temperature
and humidity that does not exceed 75
°
F and
55% R.H.
ESBDHV
Discharge Air (°F)
27
Evaporator (°F)
19
Unit Sizing (°F)
18
Btu/hr/ft
ESBDHV
Parallel
407
Conventional
426
DEFROST DATA
ESBDHV
Frequency (hr)
12
Defrost Water (lb/ft/day)
0.38
(± 15%
based on case configuration and
product loading).
O
FFTIME
ESBDHV
Temp Term (°F)
43
Failsafe (minutes)
90
E
LECTRIC OR
G
AS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
ESBDHV
CI/CO (Temp °F)
*
13
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)*
Not Recommended
*Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1
1
/
2
Merchandiser Liquid Line (in.)
3
/
8
Merchandiser Suction Line (in.)
5
/
8
Estimated Charge (lb)**
ESBDHV
4 ft
0.8
6 ft
1.2
8 ft
1.5
12 ft
2.0
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
Length Added to Lineup by
Each End and
Partition
1in.
3 of 8
P/N 0489782_A
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Refrigeration
Outlet
COIL
FA
N
FAN
22
1
/
2
(572)
18
1
/
8
(460)
52
1
/
8
(1324)
26
1
/
4
(667)
27
1
/
4
(692)
ESBDHV
29
3
/
8
(746)
33
1
/
4
(845)
12
(305)
45
1
/
4
(1149)
20
(508)
14
3
/
8
(365)
4
(102)
29
1
/
4
(743)
12
(305)
8
(203)
10
(254)
8
(203)
8
1
/
4
(210)
9
5
/
8
(245)
5
1
/
2
(140)
Dimensions shown as in. and (mm).
Impact Elite
ESBDHV
Meat & Delicatessen
Elite Curved Hinged Glass, Blower, High Volume, 3 Display Levels
NSF Certification
These merchandisers are manufactured to meet ANSI /National Sanitation
Foundation (NSF
®
) Standard #7 requirements.