CARE AND CLEANING
Long life and satisfactory performance
of any equipment is dependent upon the
care it receives. To ensure long life, proper
sanitation and minimum maintenance costs,
these merchandisers should be thoroughly
cleaned, all debris removed and the interiors
washed down, weekly.
Fan Plenum
The fan plenum is located behind the
interior back panels. Remove the back
panels to get access to the fans.
Glass Doors
Wipe inside of glass with isopropyl alcohol
and a soft cloth. Allow surface to dry
before closing door. Use of other cleaners
or abrasives may damage the surface, and/
or void the warranty. Refer to manual that
ships with doors.
Interior Surfaces
The interior surfaces may be cleaned with
most domestic detergents, ammonia based
cleaners and sanitizing solutions with no
harm to the surface.
Exterior Surfaces
The exterior surfaces should be cleaned with
a mild detergent and warm water to protect
and maintain their attractive finish. Never
use abrasive cleansers or scouring pads.
Do Not Use:
• Abrasive cleansers and scouring pads, as
these will mar the finish.
• Coarse paper towels on coated glass.
• Ammonia-based cleaners on acrylic parts.
• Solvent, oil or acidic based cleaners on any
interior surfaces.
Do:
• Remove the product and all loose debris
to avoid clogging the waste outlet.
• Store product in a refrigerated area
such as a freezer. Remove only as much
product as can be taken to the freezer in
a timely manner.
• First turn off refrigeration, then
disconnect electrical power.
• Thoroughly clean all surfaces with
soap and hot water. Do not use steam
or high water pressure hoses to wash
the interior. These will destroy the
merchandisers’ sealing causing leaks and
poor performance.
• The fan plenum is located behind the
interior back panels. The plenum should
be cleaned regularly according to store
environment conditions.
• Take care to minimize direct contact
between fan motors and cleaning or rinse
water.
• Rinse with hot water, but do not flood.
Never introduce water faster than the
waste outlet can remove it.
• Allow merchandisers to dry before
resuming operation.
• After cleaning is completed, turn
on power and refrigerant to the
merchandiser.
• Verify that merchandiser is working
properly.
MAINTENANCE
SHUT FANS OFF DURING CLEANING
PROCESS.
Do NOT use HOT water on COLD glass
surfaces. This can cause the glass to shatter
and could result in personal injury. Allow
glass fronts, ends and service doors to warm
before applying hot water.