background image

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

D5LEP

LUS

U

NLIT

L

IT

P

EG

**

Discharge Air °F

32

30

30

Evaporator °F

28

26

26

Unit Sizing °F

26

24

24

Btu/hr/ft*

D5LEP

LUS

U

NLIT

L

IT

P

EG

**

Parallel

1290

1385

1445

Conventional

1365

1465

1530

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
** Hussmann Peg Shelves (Deli only).

DEFROST DATA

Frequency Hrs

12

Defrost Water (lb/ft/day)

10.5

(± 15% 

based on case configuration and product

loading).

O

FFTIME

D5LEP

LUS

Time (minutes)

40

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONALCONTROLS

Low Pressure Backup Control
CI/CO

**

D5LEP

LUS

19°F / 9°F

Indoor Unit Only, Pressure Defrost
Termination**

48°F

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Drip Pipe (in.)

1

/

2

Liquid Line (in.)

3

/

8

Suction Line (in.)

7

/

8

Estimated Charge (lb)***

D5LEP

LUS

8 ft

3.7

12 ft

5.1

***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.

Length Added to Lineup by

Each End (in.)

1

/

2

Each Insulated Partition (in.)

1

/

2

3 of 6

P/N 0445920C

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

D5LEP

LUS

Dairy & Delicatessen

Dimensions shown as in. and (mm).

Multi-deck, 5 Display Levels, Low Front

NSF Certification

These merchandisers are manufactured to meet ANSI /National

Sanitation Foundation (NSF

®

) Standard #7 requirements. 

   

4  

(102)

 

C

O

I

L

61

(1549)

81 

3

/

8

(2066) 

45 

5

/

8

(1159)

D5LEP

LUS

FAN 

5

 

3

/

4

(146)

19

(483)

3

 

1

/

(79)

56 

1

/

4

(1429) 

7

 

1

/

2

(152) 

7

(178) 

46 

1

/

4

  (1174) 

27 

1

/

 (699)

30 

1

/

8

(765)

1

/

4

(108)

29 

1

/

 

(749)

1

/

2

(114

)

38 

5

/

8

  

(981)

3

/

 (70

)

53 

5

/

8

(1360) 

14 

1

/

8

(359)

1

/

8

(155)

Summary of Contents for D5L-EP

Page 1: ...geration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS C 0376409 Ballast Electronic 2 lamps 3 C 0376410 Ballast Electronic 3 lamps 3 D Fluorescent Lamp 4 Replace with like fixtures D5LEPLUS Data Sheet Set P N 0445920C NSF Certified March 2005 We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do n...

Page 2: ... raceway 34 5 8 878 34 5 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Outside diameter of the drip pipe 1 1 2 38 1 1 2 38 NOTE Water seal outlet must clea...

Page 3: ... Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb D5LEPLUS 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End in 1 1 2 Each Insulated Partition in 1 1 2 3 of 6 P N 0445920C HUSSMANN...

Page 4: ... Minimum Circuit Ampacity With Standard Fans 1 60 2 30 With Energy Efficient Fans 0 96 1 34 With Export Fans 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA Gas Defrost Heaters 208V NA NA NA NA Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1...

Page 5: ...k W White 120V POWER 120V NEUTRAL FIELD GROUND CASE GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light...

Page 6: ...ot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W 4 BL R R BL BL 3 BL R R BL BL 3 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 3 4 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V ...

Reviews: