background image

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

C

C

D

D

A

B

D

P/N 0445920C

Merchandisers

®

Note: Changed items have been underlined.

Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 

0315470

Fan Blade
embossing toward motor

B.

0137880

Optional Adjustable 

(2)

Refrigeration Thermostat

Item

Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

C.

0376409

Ballast, Electronic

2 lamps

(3)

C.

0376410

Ballast, Electronic

3 lamps

(3)

D.

Fluorescent Lamp

(4)

Replace with like fixtures

D5LEP

LUS

Data Sheet Set

P/N  0445920C

NSF

®

Certified

March  2005

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Summary of Contents for D5L-EP

Page 1: ...geration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS C 0376409 Ballast Electronic 2 lamps 3 C 0376410 Ballast Electronic 3 lamps 3 D Fluorescent Lamp 4 Replace with like fixtures D5LEPLUS Data Sheet Set P N 0445920C NSF Certified March 2005 We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do n...

Page 2: ... raceway 34 5 8 878 34 5 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to center of waste outlet 4 102 4 102 Outside diameter of the drip pipe 1 1 2 38 1 1 2 38 NOTE Water seal outlet must clea...

Page 3: ... Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb D5LEPLUS 8 ft 3 7 12 ft 5 1 This is an average for all refrigerant types Actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End in 1 1 2 Each Insulated Partition in 1 1 2 3 of 6 P N 0445920C HUSSMANN...

Page 4: ... Minimum Circuit Ampacity With Standard Fans 1 60 2 30 With Energy Efficient Fans 0 96 1 34 With Export Fans 230V 50Hz 0 96 1 34 Maximum Over Current Protection 120V 20 20 Export 230V 50Hz 15 15 Electric Defrost Heaters 208V 1Φ Φ NA NA NA NA Gas Defrost Heaters 208V NA NA NA NA Standard Lighting 8 ft 12 ft 8 ft 12 ft 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Row Rail 1 02 1...

Page 5: ...k W White 120V POWER 120V NEUTRAL FIELD GROUND CASE GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light...

Page 6: ...ot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W 4 BL R R BL BL 3 BL R R BL BL 3 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 3 4 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V ...