background image

rev. 0608 

9

1.1  The following recommendations are made 

for the purpose of arriving at easily taken and 

understood data which, coupled with other 

observations, may be used to determine whether 

a display refrigerator is working as intended:

a)  INSTRUMENT - A stainless steel stem-type 

thermometer is recommended and it should 

have a dial a minimum of 1 inch internal 

diameter. A test thermometer scaled only 

in Celsius or dually scaled in Celsius and 

Fahrenheit shall be accurate to 1°C (1.8°F). 

Temperature measuring devices that are 

scaled only in Fahrenheit shall be accurate to 

°F. The thermometer should be checked for 

proper calibration. (It should read 3°F when 

the stem is immersed in an ice water bath).

b)  LOCATION - The probe or sensing element 

of the thermometer should be located in 

the airstream where the air first enters the 

display or storage area, and not more than  

1 inch away from the surface and in the 

center of the discharge opening.

c)  READING - It should first be determined 

that the refrigerator is refrigerating and has 

operated at least one hour since the end 

of the last defrost period. The thermometer 

reading should be made only after it has 

been allowed to stabilize, i.e., maintain a 

constant reading.

d)  OTHER OBSERVATIONS - Other 

observations should be made which may 

indicate operating problems, such as 

unsatisfactory product, feel/appearance.

e)  CONCLUSIONS - In the absence of any 

apparent undesirable conditions, the 

refrigerator should be judged to be operating 

properly. If it is determined that such 

condition is undesirable, i.e., the product is 

above proper temperature, checks should be 

made for the following:

1.  Has the refrigerator been loaded with 

warm product?

.  Is the product loaded beyond the “Safe 

Load Line” markers?

3.  Are the return air ducts blocked?

4.  Are the entering air ducts blocked?

5.  Is a dumped display causing turbulent air 

flow and mixing with room air?

6.  Are spotlights or other high intensity 

lighting directed onto the product?

7.  Are there unusual draft conditions (from 

heating/air-conditioning ducts, open 

doors, etc.)?

8.  Is there exposure to direct sunlight?

9.  Are display signs blocking or diverting 

airflow?

10. Are the coils of the refrigerator iced up?

11. Is the store ambient over 75°F, 55% RH 

as set forth in ASHRAE Standard 7 and 

ASHRAE Standard 117?

1. Are the shelf positions, number, and size 

other than recommended by Hussmann?

13. Is there an improper application or control 

system?

14. Is the evaporator fan motor/blade 

inoperative?

15. Is the defrost time excessive?

16. Is the defrost termination, thermostat (if 

used) set too high?

17. Are the refrigerant controls incorrectly 

adjusted?

18. Is the air entering the condenser above 

design conditions? Are the condenser fins 

clear of dirt, dust, etc.?

19. Is there a shortage of refrigerant?

20. Has the equipment been modified 

to use replacements for CFC-1, 

CFC-50 or other refrigerant? If so, 

have the modifications been made in 

accordance with the recommendations 

of the equipment manufacturer? Is the 

refrigerator charged with the proper 

refrigerant and lubricant? Does the system 

use the recommended compressor?

appendix d. - recommendations to User

1.0  Hussmann Corporation provides instructions 

and recommendations for proper periodic 

cleaning. The user will be responsible for 

such cleaning, including the cleaning of low 

temperature equipment within the compartment 

and the cooling coil area(s). Cleaning practices, 

particularly with respect to proper refrigerator 

unloading and warm-up, must be in accordance 

with applicable recommendations.

appendices (Cont'd)

Summary of Contents for CR3-F

Page 1: ...ce and Self service Meat Fish case with rear storage P N R3 CR3 M F 0608 INSTALLATION OPERATION GUIDE CHINO R3 CR3 M F Combination Service and Self service Meat Fish case with rear storage Rev 0608 In...

Page 2: ...nt Case R3 F Refrigerated Service Top for Fish with Gravity Coil and Refrig Self Service Front Case CR3 M Refrigerated Service Top for Meat with Gravity Coil and Refrig Self Service Front Case CR3 F R...

Page 3: ...2 3 1 2 12 3 4 19 5 8 8 39 1 4 10 3 4 35 3 8 18 53 3 8 26 1 2 16 26 3 8 Optional Dry Refrigerated or no storage 19 3 8 4 R3 F Service Fish Case with Straight Glass Self Service Front Gravity Coil and...

Page 4: ...OD LEG BRACES WHERE SUPPORT IS BEST TO PREVENT DAMAGE TO THE CASE 1 It is imperative that the cases be leveled from front to back and side to side as they are being joined beginning with the first cas...

Page 5: ...Be careful to observe the area where the clamp is being tightened so that the case is not damaged as pressure is applied 8 Attach cases together via 2 bolts located in the end leg tubes at the base of...

Page 6: ...x screws along glass clamp may have loosened during shipping Retighten all glass clamp screws before opening glass Level Minitop Hardware IF GLASS DOES NOT CLOSE STAY OPEN PROPERLY Level MINI TOP HARD...

Page 7: ...If pinched at the bottom Gap is more narrow at the bottom than at the top Adjust outside hinges Center hinge stationary This diagram indicates that raising the outside hinges widens the gap at the bot...

Page 8: ...most cases the center hinge is the first candidate but if the arm minicam is at its maximum or minimum position then obviously the outer hinges must be used See Vertical Adjustment of Glass Vertical...

Page 9: ...op edge or center with 3 8 long sheet metal screws If needed use silicone sparingly to caulk the joint trim and exterior body panels with an appropriate colored silicone to ensure that a cleanable and...

Page 10: ...3 M F 0608 10 Installation Cont d Scale Stand Installation Instructions 1 Set Scale Stand to desire location 2 Drill holes and screw in place with screws provided Hex Tek S S 10 16 X Note Use hole pat...

Page 11: ...sure 10 inches from top of the case Note Line up 6 inch mark with 10 inch mark Step 3 Use bracket center hole to align with cross mark Note Use pencil marker to mark hole pattern HOLE PATTERN Step 4 D...

Page 12: ...ion Cont d Step 6 Install upper support bracket Step 7 Mount wrap board on top of bracket using a spacer to have a gap between rear wall and board Step 8 Screw bracket into wrap board screws provided...

Page 13: ...mper slide into the channel Step 3 Starting on one end while inserting the bumper push it up against the end cap to prevent the bumper from shrinking after installation when it gets cold Step 4 As you...

Page 14: ...are positioned within the base grooves Roll vinyl top over full length of base then tap with rubber mallet to ensure vinyl is securely locked into the base 2b Rigid Top Snap the Rigid Top over the Rig...

Page 15: ...th of base then tap with rubber mallet to ensure vinyl is securely locked into the base 2b Rigid Top Snap the Rigid Top over the Rigid Base 3 If necessary wipe clean with any household cleaning produc...

Page 16: ...legs are positioned within the base grooves Roll vinyl top over full length of base then tap with rubber mallet to ensure vinyl is securely locked into the base 2b Rigid Top Snap the Rigid Top over t...

Page 17: ...sed as part of the condensate drain to prevent air leakage or insect entrance Store plumbing system floor drains should be at least 14 off the center of the case to allow use of the P TRAP pipe sectio...

Page 18: ...c Expansion Valve EEV Optional A wide variety of electronic expansion valves and case controllers can be utilized Please refer to EEV and controller manufacturers information sheet Sensors for electro...

Page 19: ...are operating at the proper temperature Allow merchandiser to operate a minimum of 6 hours before stocking with any product 5 When stocking never allow the product to extend beyond the recommended loa...

Page 20: ...ct cleaning agents or cleaning cloths can cause micro scratching of the surface causing the plastic to haze over time Cleaning Hussmann recommends using a clean damp chamois or a paper towel marketed...

Page 21: ...and hot water 2 Rinse with hot water but DO NOT flood or spray glass If you are working from the rear of the case the front glass is lift up glass and is NOT sealed IT WILL LEAK Keep all water within...

Page 22: ...R3 CR3 M F 0608 22 Electrical Wiring Diagrams R3 2002 Meat 4 W0180016 6 W0180017 8 W0180018 12 W0180020 24VAC Solenoids 12 1H10019...

Page 23: ...IL ASSY VA 08 0 120V 0 8A 225 02 0513 CAP OFF WIRE IF UNUSED T STAT 1 225 01 0707 SUCTION SOLENOID 1 225 01 3202 RJ 45 NETWORK JACK 125 01 0200 125 01 0203 125 01 0204 COMMUNICATION CONNECTION TO BE D...

Page 24: ...25 01 3202 LOWER FRONT SECTION SHELF LIGHT OPTION A COIL ASSEMBLY 0 8A 120V 225 02 1333 BALLAST 125 01 3266 FULHAM LH3 120 L F21T5 36 125 03 1128 F21T5 36 125 03 1128 RJ 45 NETWORK JACK 125 01 0200 12...

Page 25: ...5 48 125 03 1131 F28T5 48 125 03 1131 LOWER FRONT SECTION SHELF LIGHT OPTION A M M BONE COIL ASSY VA 08 0 120V 0 8A 2 225 02 0513 BALLAST 125 01 3266 FULHAM LH3 120 L RJ 45 NETWORK JACK 125 01 0200 12...

Page 26: ...TAT 1 225 01 0707 SUCTION SOLENOID 1 225 01 3202 M M F28T5 48 125 03 1131 F28T5 48 125 03 1131 LOWER FRONT SECTION SHELF LIGHT OPTION A BOHN COIL ASSY VA 012 0 1 6A 120V 2 225 02 1333 BALLAST 125 01 3...

Page 27: ...NOT WIRE A HEATING ELEMENT TO THE FIXED GLASS MEAT FISH R 3 2002 CASES LOWER FRONT SECTION OPTION B REFRIGERATED REAR STORAGE OPTION C TAG REAR STORAGE T STAT 1 225 01 0707 SUCTION SOLENOID 1 1H08061...

Page 28: ...orm a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed with a refrigerant acc...

Page 29: ...warm product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air flow and mix...

Page 30: ...erature recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising products to ensure that pot...

Page 31: ...________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________...

Reviews: