background image

IGSS-RCD-0105

2

/Chino

A publication of
Hussmann

®

 Chino

13770 Ramona Avenue • Chino, California 91710
(909) 628-8942 FAX
(909) 590-4910
(800) 395-9229

Keep this booklet with the case at all times for future reference.

THIS BOOKLET CONTAINS INFORMATION ON:

RCD - Drop in refrigerated counter-top self service
case.

SHIPPING DAMAGE

All equipment should be thoroughly examined for
shipping damage before and during unloading.
This equipment has been carefully inspected at our
factory and the carrier has assumed responsibility for
safe arrival. If damaged, either apparent or concealed,
claim must be made to the carrier.

APPARENT LOSS OR DAMAGE

If there is an 

obvious loss or damage

, it must be noted on

the freight bill or express receipt and signed by the
carrier’s agent; otherwise, carrier may refuse claim. The
carrier will supply necessary claim forms.

CONCEALED LOSS OR DAMAGE

When loss or damage

 is not apparent until after equip-

ment is uncrated

, a claim for concealed damage is made.

Make request in writing to carrier for inspection within
15 days, and retain all packaging. The carrier will supply
inspection report and required claim forms.

SHORTAGES

Check your shipment for any possible shortages of
material. If a shortage should exist and is found to be
the responsibility of Hussmann Chino, 

notify Hussmann

Chino

. If such a shortage involves the carrier, 

notify the

carrier immediately,

 and request an inspection. Hussmann

Chino will acknowledge shortages within ten days from
receipt of equipment.

HUSSMANN CHINO PRODUCT CONTROL

The serial number and shipping date of all equipment
has been recorded in Hussmann’s files for warranty and
replacement part purposes. All correspondence pertain-
ing to warranty or parts ordering must include the
serial number of each piece of equipment involved, in
order to provide the customer with the correct parts.

The Hussmann warranty is printed on the back

of this guide.

General Instructions

Table of Contents

General Instructions ................................................. 2
Cut & Plan Views ....................................................... 3
Installation ................................................................. 5
Plumbing .................................................................... 5

WASTE OUTLET AND P-TRAP .............................................................................. 5
Condensing Unit Installation Requirements ....................................................... 5

Refrigeration ............................................................. 6

T-STAT LOCATION .................................................................................................. 6

Electrical .................................................................... 7

WIRING COLOR CODE ......................................................................................... 7

User Information ...................................................... 8

STOCKING .............................................................................................................. 8
CASE CLEANING .................................................................................................... 8
PLEXIGLASS & ACRYLIC CARE .............................................................................. 9

Maintenance .............................................................. 9

ELECTRICAL PRECAUTIONS ................................................................................... 9
REPLACING FLUORESCENT LAMPS ....................................................................... 9

Electrical and Refrigeration Specifications ............ 10
Electrical Schematics ............................................... 11
Appendices ................................................................ 13

APPENDIX A. – Temperature Guidelines ............................................................ 13
APPENDIX B. – Application Recommendations .................................................. 13
APPENDIX C. – Field Recommendations - ......................................................... 13
APPENDIX D. – Recommendations to user - .................................................... 14

Summary of Contents for Chino RCD

Page 1: ...Chino RCD DROP IN REFRIGERATED SELF SERVICE REV 0105 Installation Operation Manual RCD DROP IN REFRIGERATED SELF SERVICE P N IGSS RCD 0105 INSTALLATION OPERATION GUIDE...

Page 2: ...or any possible shortages of material If a shortage should exist and is found to be the responsibility of Hussmann Chino notify Hussmann Chino If such a shortage involves the carrier notify the carrie...

Page 3: ...1 4 19 1 2 14 1 4 9 Fan 46 43 11 2 11 2 18 1 2 5 1 4 25 RCD 25 Shown with light 25 depth and 9 height options 20 1 2 6 7 8 RCD Remote Shown with Options Scale 3 4 Optional Light Optional Step 38 3 8 2...

Page 4: ...sArmstrong sArmaflex b Where condensate drains are located in dead air spaces between refrigerators or between a refrigerator and a wall provide means to prevent freezing The water seal should be insu...

Page 5: ...from left end of case Remove product racks Remove refrigeration and drain access panels labeled TX valve mechanical only and drain are located under each access panel at end of the case ELECTRONIC Th...

Page 6: ...e top The switch controlling the lights the plug provided for digital scale and the thermometer are located at the rear of the case mullion FIELD WIRING SERIAL PLATE AMPERAGE Field Wiring must be size...

Page 7: ...ting will cause serious product loss Discoloration dehydration and spoilage can be controlled with proper use of the equipment and handling of product Product temperature should always be maintained a...

Page 8: ...F U R R TIPS TROUBLESHOOTING Before calling for service check the following 1 Check electrical power supply to the equipment for connection 2 Check fixture loading Overstocking case will affect its pr...

Page 9: ...125 18 36 30 125 35 Forced 4 1 2 Axial 40 3 1 44 Air 8 3 16 Deep 4 175 18 36 30 125 35 Forced 4 1 2 Axial 40 3 54 Air 3 3 6 175 18 36 30 125 35 Forced 4 1 2 Axial 40 3 72 Air 4 3 8 175 18 36 30 125 35...

Page 10: ...elf Contained w Ref Rear Storage 120V 15 0 MCA 60Hz Front Display Evaporator 2 4 Axial Fan 0000 1212 Note case must be grounded Ballast MagneTek B260i120RH F48T12 SPX30 M Cap red blue blue brown orang...

Page 11: ...Revisions No Description Checked By By RCD 5 220V Remote Case Wiring Diagram W1910005 Drop In Cold Sandwich Deli Display 220V 50Hz M Evaporator 4 Axial Fan 125 01 3142 220V 0 5A Anti Sweat Heating Tap...

Page 12: ...l temperature performance Coils should be properly fed with a refrigerant according to manufacturer s recommendations b Observation of outside influences such as drafts radiant heating from the ceilin...

Page 13: ...ns clear of dirt dust etc 19 Is there a shortage of refrigerant 20 Has the equipment been modified to use replacements for CFC 12 CFC 502 or other refrigerant If so have the modifications been made in...

Page 14: ...comes in contact with the tool or equipment i Make sure that all refrigeration equipment is installed and adjusted in strict accordance with Hussmann s recommendations j See that all storage and refr...

Page 15: ...der this warranty shall be limited to a period not to exceed five years from date of factory shipment On Hussmann refrigeration systems an additional 4 year extended warranty for the motor compressor...

Page 16: ...cular unit They can be found on a small metal plate on the unit Please note them below for future reference MODEL SERIAL NUMBER Chino Additional copies of this publication may be obtained by contact i...

Reviews: