background image

Installation manual

 

                                                                                                              

H1 Self Contained Multideck

  

 

_________________________________________________________________________________________________________________________                                                                                                                                                                                                                                                      
Page 

7

 

                                                                                                              Hussmann

 

 

 

NOTE

 

It is important that all cases are level for correct 

case operation. 

 

 
 
 
 
 
 
 

Figure 6     Case levelling 

 

 
Mounting fixtures 

 
Replace any racks and shelves etc that may have been removed during installation, to store requirements 
 

 

NOTE

 

Incorrect shelf configurations may 

compromise case performance.

 

 

Commissioning 

 

Cleaning case  

 

 

Remove the PVC protective coating on stainless steel, where applicable 

 

 

Remove any residue, silicon or tape marks with a cloth moistened with rubbing alcohol 

 

 

Remove all debris from in and around the case 

 

Make sure 

all

 adjusting feet, 

NOT just the ones at the end of 
the case, are adjusted firmly to 
ensure case does not sag 

Summary of Contents for Austral H1

Page 1: ...ontained Multideck Case Installation Manual Reference IM 1006 The following models are covered by this Manual H1 10 H1 14 66 Glendenning Road Glendenning NSW 2761 PO Box 42 Doonside NSW 2767 t 61 2 88...

Page 2: ...e installation 2 case services dimensions 2 Operating environment 5 Handling and transporting cases 5 Shipping damages and shortages 6 Installation 6 Positioning and levelling Commissioning 7 Cleaning...

Page 3: ..._____________________________________________________________________________________ Hussmann Page 2 Pre installation Warning All refrigeration electrical and plumbing work must be carried out by lic...

Page 4: ...Self Contained Multideck _________________________________________________________________________________________________________________________ Page 3 Hussmann H1 10 Foot Print H1 14 Foot Print fi...

Page 5: ..._______________________________________________________________ Hussmann Page 4 Group Installations figure 2 acceptable group configurations NOTE Installing into an alcove is not recommended and will...

Page 6: ...Cases must not be positioned in areas that may be subject to heat or air currents such as ventilation ducts open doors or windows direct sunlight electric fans or ovens etc Otherwise the cabinet may s...

Page 7: ...trims etc are accounted for Immediately report any shipping damage to the carrier and inform Hussmann of any short supplies Installation NOTE Information in this manual is to be followed in conjuncti...

Page 8: ...any racks and shelves etc that may have been removed during installation to store requirements NOTE Incorrect shelf configurations may compromise case performance Commissioning Cleaning case Remove th...

Page 9: ...ioning Plan and risk assess the decommissioning process to include the following Isolate the case Removal of the case is to be in the reverse order of installation listed previously Disposal Case disp...

Page 10: ...n the case as this may result in personal injury and or case damage 1 Remove stock from the case and store below 5 C 2 Turn off power to the case electrical 3 Remove all price tickets and any foreign...

Page 11: ...1 Check that all case panels and trims are secure and undamaged 2 Check for rust and paint damage 3 Ensure all cable connections including screw terminals earth leads and straps are secure 4 Ensure in...

Page 12: ...t remove the protection grill clean it very carefully avoid touching other components and put the grill back in its place 14 Clean the dissipater tray To reach the dissipater tray remove the protectio...

Page 13: ...need more frequent defrost Case shelf arrangement has been deviated significantly from original specified setup Re do the shelf arrangement as per the original specification Air Return is blocked by...

Page 14: ...ce provider Rust salt or other deposits bridging the sensor input signal The sensor tip s short circuited The compressor never stops The condenser is dirty Contact service provider The fluid is missin...

Page 15: ...ched or crushed during the positioning of base trays shelves stock Staff must be trained in the correct procedures for setting up cases and ergonomic practices Slipping Drain may leak or become blocke...