5. Make sure that the loudspeaker and the sealing is in
its correct position (G).
G
CAUTION: The rubber sealing is not
symmetrical. Make sure to assemble with the
flat side (F) against the front side of the
loudspeaker.
F
7.9 The microphone
7.9.1 To disassemble the microphone
CAUTION: Note how the cables and
components are installed when you
disassemble the microphone.
Note: Make sure that the microphone and the sealing is
in position.
1. Disassemble the left earmuff. Refer to step 1-4 in
disassemble the left earmuff on page 13.
2. Disassemble the right earmuff. Refer to step 1-4 in
To disassemble the right earmuff on page 12.
3. Right earmuff: Disconnect the microphone cable
from the circuit board at position F.
F
4. Left earmuff: Disconnect the microphone cable from
the circuit board at position H.
H
5. Remove the microphone (A) and wind filter (B).
A
B
893 - 001 -
Repair instructions - 19