fault occurs. Refer to
for
information about at which current the PRCD engages.
The red light shows that the PRCD is on and that the
product can be started. If the red light does not show,
push the RESET button.
To examine the PRCD
WARNING:
Not applicable for 110V
type sold in United Kingdom and Ireland.
PRCD on page 8
.
WARNING:
The PRCD must be
examined each time the power plug is
connected to a power outlet.
WARNING:
If the PRCD must be
repaired, always speak to an approved
Husqvarna service agent.
1. Connect the power plug of the product to a power
outlet.
2. Push the "RESET" button. The indicator above the
button is red when the current is connected.
3. Start the product, refer to
page 13
.
4. Push the "TEST" button. If the product stops, the
PRCD operates correctly.
Isolation transformer
Note:
Applicable for 110V type sold in United
Kingdom and Ireland.
Do not operate the 110V type of the product without
isolation transformer that refers to EN/IEC 61558-1 and
EN/IEC 61558-2-23.
The isolation transformer must have ground wires on the
230V and the 110V side.
Power switch
The power switch is used to start and stop the product.
To do a check of the power switch
1. Connect the power plug of the product to a power
outlet.
2. Push the power switch to start the product.
1473 - 001 - 04.04.2022
9
Summary of Contents for DM 230
Page 97: ...1473 001 04 04 2022 97 ...
Page 98: ...98 1473 001 04 04 2022 ...
Page 99: ...1473 001 04 04 2022 99 ...