50 - English
6. MENU FUNCTIONS
When the function is selected the mower will
immediately follow the boundary wire, guide 1 or
guide 2, depending on which one it finds first, in
to the charging station. If there is a passage and
the mower can not run through it, the
Corridor
width
value is set too high. When Test IN is
activated, the mower runs at the greatest
distance from the wire that the selected corridor
width permits.
The adjacent picture shows how Automower
®
negotiates a passage when a value of 8 is set for
the
Corridor width
, but not when a value of 10 is
set.
•
Test OUT (3-2-5)
The
Test OUT (3-2-5)
function is used to try
different charge exit settings and to find out how
far it is from the charging station to a remote
area.
To test the settings for
Follow loop out (3-2-1)
:
• Set
Proportion
to 100 % for the most remote
area to be tested and 0 % for the other areas.
Place Automower
®
in the charging station and
select
Test OUT (3-2-5)
. The mower will now
leave the charging station directly according to
the stated direction and start mowing after the
stated distance. Reset the
Proportion
values
when testing is finished.
To find out the distance from the charging station
to a remote area:
• State a distance that easily exceeds the true
distance. The maximum distance that can be
stated is 500 metres. Set
Proportion
to 100 % for
the areas where the distance is to be measured
and 0 % for the other areas. Place Automower
®
in the charging station and select
Test OUT
(3-2-5)
. The mower will now leave the charging
station directly according to the stated direction.
The distance will be shown on the display,
stated in metres, as the mower runs. Stop the
mower after the required distance and read the
distance. Enter the number of metres shown in
Distance for the area in question. Reset the
Proportion
values when testing is finished.
IMPORTANT INFORMATION
When Test IN (3-2-4) is used, the house icon
on the display will come on and the mower
will remain in the charging station. Press the
Home button to return to operations.
10
8
3-2-4
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT