![Husqvarna 362XP Workshop Manual Download Page 21](http://html.mh-extra.com/html/husqvarna/362xp/362xp_workshop-manual_170984021.webp)
ELECTRICAL SYSTEM
English – 19
Reassembly
Assemble the ignition system as follows:
1. Locate the flywheel on the crankshaft. Turn it gently until
the key on the flywheel mates with the recess in the shaft.
2. Fit the flywheel washer and nut. Tighten the nut to 35 Nm.
See fig. 5.
3. Locate the ignition module (B) without tightening the
bolts.
4. Rotate the flywheel so that the magnet (G) is beside the
ignition module. See fig. 6.
5. Insert the feeler gauge (H) (0.3 mm) into the air gap
between the ignition module and flywheel magnet. The
clearance applies only to the two lower pegs on the
ignition module. See figs. 6 and 7.
6. Push the ignition module towards the flywheel and
tighten the bolts to 4 Nm.
7. Fit the cable guide (D) and press in the HT lead into place.
Remove the piston stop and connect the HT lead to the
spark plug.
8. Pull out the blue lead, thread it under the HT lead at F and
push home the cable clip onto the ignition module. See
fig. 1.
9. Press the blue lead into the groove in the cable guide.
See fig. 1.
10.Attach the pawls (E) for the recoil starter. See fig. 1.
11. Attach the cylinder cover and the recoil starter assembly.
See page 17.
Fig. 5
Fig. 6
H
Hu
s
qv
arn
a
Fig. 7
H
0.3 mm
B
B
G
G
E
Stop switch
The stop switch is described in the section ”Safety equipment”.
See page 14.