English –
17
!
WARNING!
No service procedures must be conducted on the engine or cutting unit unless:
•
The engine is switched off.
•
The ignition key is removed.
•
The ignition cable is removed from the plug.
•
The parking brake is applied.
•
The cutting unit is disengaged.
Maintenance
50
25
100
MAINTENANCE
Page
Maintenance interval
in hours
Daily
mainte-
nance
before start
Maintenance schedule
The following is a list of the maintenance which should be conducted on the machine. For the items which
are not described in these instructions go to an authorised service workshop.
Check the engine’s oil level
20
●
Check the engine’s cooling air inlet
20
●
Check the fuel pump’s air filter
20
●
Check the steering wires
21
●
Check the brakes
22
●
Check the battery
23
●
Check the safety system
23
●
Check screws and nuts
–
❍
Check for fuel and oil leakage
–
❍
Clean the air filter’s pre-filter (foam plastic)
2)
24
●
Check the cutting unit
25
●
Check the tyre pressures (60 kPa)
30
●
Change the engine oil
1)
31
●
Adjust the brakes – Rider 11 and Rider 11 Bio
22
●
Check the V-belts
–
❍
Check the transmission’s cooling flanges –
–
❍
Rider 13 H and Rider 13 H Bio
Check the transmission’s oil level
23
●
Adjust the brakes – Rider 13 H and Rider 13 H Bio
22
●
Lubricate joints and shafts
3)
31
●
Check and adjust the throttle wire
33
●
Clean the cooling flanges on the engine and
–
❍
transmission
2,4)
Replace the air filter’s pre-filter and paper filter
2)
24
●
Replace the fuel filter
33
●
Replace the plug
–
❍
1)
First change after 5 hours.
2)
During dusty conditions cleaning and replacement should be more frequent.
3)
For daily use of the
machine lubrication should be conducted twice a week.
4)
Conducted by authorised service workshop.
●
= Described in these instructions.
❍
= Not described in these instructions.
Summary of Contents for 11 Bio/13 H Bio
Page 40: ...Svenska 31 ...
Page 41: ...40 English 3 6X ...
Page 42: ...Svenska 31 ...
Page 43: ...2000W37 3 6X ...