20
104 72 47-26
Needle point
6. Basic setting - the step motor of the needle
Check
1. Insert a new needle 90 in the machine.
2. Set the needle in its upper turning position.
3.The needle should always get to the centre position, when the main
switch is turned on repeatedly.
Check
Get into the service program of the machine.
The needle should be in its upper turning position.
Touch
Needle -
, row 1.
The needle should now take its centre position in the
presser foot.
Touch
Needle -
, row 1.
The needle shall now take its left position.
The gap between the segment (A) and the calibration stop (B)
should now be zero (0 mm).
Note!
The position of the eccentric.
Settings