Husky IMPACT DRIVER Use And Care Manual Download Page 2

 

Table of Contents 

 

 

 

Table of Contents .................................................. 2

 

Safety Information ............................................... 2

 

Work Area Safety ............................................................ 2

 

Personal Safety ............................................................... 2

 

Personal Safety (Continued) ............................................ 3

 

Air Tool Safety ................................................................ 3

 

Warranty ................................................................ 3

 

Husky Air Tool Limited Two-Year Warranty .................... 3

 

Additional Limitations..................................................... 3

 

Specifications ........................................................ 4

 

Installation ............................................................. 4 
Application / Operation ........................................ 5 
Maintenance .......................................................... 5 
Exploded View & Parts List .................................. 6 
Troubleshooting .................................................... 7 

 

 

 

 

 

 

 

 

 

Safety Information 

 

 

 

WORK AREA SAFETY 

1.

 

Keep your work area clean and well lit. Ensure floors are 
not slippery from wax or dust. 

2.

 

Do not operate power tools in explosive atmospheres, 
such as in the presence of flammable liquids, gases, or 
dust. Power tools create sparks which may ignite the 
dust or fumes. Keep bystanders, children, and visitors 
away while operating tools. Distractions can cause you 
to lose control. 

3.

 

Always disconnect the air supply and power supply 
before making adjustments, servicing a tool, changing 
an accessory or when a tool is not in use. 

4.

 

For further information on the safe use of air tools, we 
advise you to obtain a copy of CAGI B186.1-2009 from 
Husky Air Tools 
851 Jupiter Park Lane 
Jupiter, Florida 33458 (877)260-1630  
 

 

PERSONAL SAFETY 

 

WARNING:

 Operating any power tool can result in 

foreign objects being thrown into your eyes, which 

can result in severe eye damage. Before beginning 
operation, always wear safety goggles, safety 

glasses with side shields, or a full face shield when 

needed. Always use eye protection marked to 

comply with ANSI Z87.1 

 

 

WARNING:

 This product contains chemicals known 

to the State of California to cause cancer and birth 

defects or other reproductive harm. Wash hands 
after handling. 

1.

 

Use safety equipment. Always wear eye protection with 
side shields when operating power tools. Dust mask, 
nonskid safety shoes, hard hat, or hearing protection 
must be used for appropriate conditions. 

2.

 

Stay alert when operating a power tool. Do not use the 
tool while tired or under the influence of drugs, alcohol, 
or medication. 

Summary of Contents for IMPACT DRIVER

Page 1: ...igned to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Husky Item 000 000 Model H4340 USE AND CARE GUIDE IMPACT DRIVER Questions problems missing parts Before returning to the store call Husky Air Tools Customer Service 8 a m 5 p m EST Monday Friday 1 877 260 1630 HUSKYTOOLS COM ...

Page 2: ...hanging an accessory or when a tool is not in use 4 For further information on the safe use of air tools we advise you to obtain a copy of CAGI B186 1 2009 from Husky Air Tools 851 Jupiter Park Lane Jupiter Florida 33458 877 260 1630 PERSONAL SAFETY WARNING Operating any power tool can result in foreign objects being thrown into your eyes which can result in severe eye damage Before beginning oper...

Page 3: ...operation is dusty Warranty HUSKY AIR TOOLS LIMITED TWO YEAR WARRANTY If within two years from the date of purchase this Husky air tool product fails due to a defect in materials or workmanship please immediately contact the Customer Service Team at 877 260 1630 8am to 5pm EST M F except normal Holidays Do not return the air tool to the store Please be prepared to send the product postage prepaid ...

Page 4: ... air hose is required up to a length of 8 ft If more length is required a 1 2 air hose should be connected to the 3 8 hose to ensure the tool has the necessary air supply Be sure all hoses and fittings are the correct size and tightly secured Before the tool is connected to the air supply clear the air hose of accumulated dust and moisture Before removing a tool for service or changing sockets mak...

Page 5: ...he tool pointed away from you pull the coupler sleeve back The bit can be removed Driving or Removing Screws Place the direction of rotation selector in the correct position for the operation Hold the impact driver with one hand Place the bit on the screw head and slowly depress the switch trigger Start the bit slowly for more control As screw is driven impacting will begin Maintenance Lubrication...

Page 6: ...6 Exploded View Replacement Parts ...

Page 7: ...h quick connect fitting This causes additional pressure drops and reduces the tool power Directly connect the hoses together Worn rotor blade in motor Replace rotor blade Worn ball bearing in motor Remove and inspect bearing for rust dirt and grit Replace or clean and grease bearing with bearing grease Moisture blowing out of tool exhaust Water in tank Drain tank See air compressor manual Oil tool...

Page 8: ...uestions problems missing parts Before returning to the store call Husky Air Tools Customer Service 8 a m 5 p m EST Monday Friday 1 877 260 1630 HUSKYTOOLS COM Retain this manual for future use H4340 2012 ...